−40 °C Desiccant Pressure Dew Point

Estimate moisture removed with a −40 °C desiccant target on an industrial dry-air branch.

Inputs

View results ↓
Intake air
°C
%
NL/min
Cooling and drying
bar(g)
°C
°C
h/day

Results

Edit inputs ↑
Moisture removal from intake to outlet PRESS. DP -40 °CATM. DP -57.83 °CAFTERCOOLER 199.3 L/dayTOTAL DRAIN 199.3 L/day AIRFLOW INTAKE 13.35 kg/h AFTERCOOLER 9.963 kg/h DRYER 3.381 kg/h OUTLET 6.5e-3 kg/h DRAIN REGEN. VAPOR INLET WATER REMOVED 99.95 % 0% MASS BALANCE 100%
Moisture removal from intake to outlet
Outlet pressure dew point
-40 °C
Atmospheric dew point
-57.834 °C
Aftercooler liquid drain
199.26 L/day
Total collected liquid
199.26 L/day
Intake saturation vapor pressure
0.04483 bar(a)
Inlet water vapor
13.35 kg/h
Water removed at aftercooler
9.963 kg/h
Water removed by dryer
3.3809 kg/h
Outlet water vapor
0.0065314 kg/h
Liquid collected at dryer
0 L/day
Total removal as liquid equivalent
266.88 L/day

Formula and assumptions

Compute saturation and intake moisture

Psat = 611.2 exp(aT/(b + T)) · w = 0.621945 Pv/(Pabs − Pv)

T is in °C and vapor pressures are in Pa. Magnus uses a = 17.62 and b = 243.12 over water, and 22.46 and 272.62 over ice below freezing. Enter relative humidity with respect to the phase used. The dry-air flow establishes dry-air mass.

Track water through both stages

Water removed = dry-air mass flow × change in humidity ratio

Limit the entering humidity ratio to saturation at each stage’s pressure and target temperature. A refrigerated dryer’s cold separator can drain liquid. A desiccant target is a pressure dew point, and regeneration typically exhausts the removed water as vapor. Drain estimates use about 1 kg of water per liter and the entered daily hours.

Find pressure and atmospheric dew points

Pv,out = Pline × wout/(0.621945 + wout) · Pv,atm = Pv,out × Pₐₜₘ/Pline

Invert the saturation equation at each vapor pressure. Below freezing the result is a frost point. Values below −65 °C extrapolate the ice fit. ISO 8573-1 class verification requires measured air quality at the point of use.

Flow labels use dry gas at 101.325 kPa, with 60 °F for SCFM and 0 °C for normal metric flow. See all unit conventions.

Worked examples