Higher-Pressure Process Air

Estimate moisture removal at 13.5 bar gauge with a moderate ambient humidity.

Inputs

View results ↓
Intake air
°C
%
NL/min
Cooling and drying
bar(g)
°C
°C
h/day

Results

Edit inputs ↑
Moisture removal from intake to outlet PRESS. DP 4 °CATM. DP -26.09 °CAFTERCOOLER 92.03 L/dayTOTAL DRAIN 109.9 L/day AIRFLOW INTAKE 6.281 kg/h AFTERCOOLER 5.113 kg/h DRYER 0.9903 kg/h OUTLET 0.1784 kg/h DRAIN DRAIN INLET WATER REMOVED 97.16 % 0% MASS BALANCE 100%
Moisture removal from intake to outlet
Outlet pressure dew point
4 °C
Atmospheric dew point
-26.088 °C
Aftercooler liquid drain
92.029 L/day
Total collected liquid
109.85 L/day
Intake saturation vapor pressure
0.037711 bar(a)
Inlet water vapor
6.2814 kg/h
Water removed at aftercooler
5.1127 kg/h
Water removed by dryer
0.99025 kg/h
Outlet water vapor
0.17837 kg/h
Liquid collected at dryer
17.825 L/day
Total removal as liquid equivalent
109.85 L/day

Formula and assumptions

Compute saturation and intake moisture

Psat = 611.2 exp(aT/(b + T)) · w = 0.621945 Pv/(Pabs − Pv)

T is in °C and vapor pressures are in Pa. Magnus uses a = 17.62 and b = 243.12 over water, and 22.46 and 272.62 over ice below freezing. Enter relative humidity with respect to the phase used. The dry-air flow establishes dry-air mass.

Track water through both stages

Water removed = dry-air mass flow × change in humidity ratio

Limit the entering humidity ratio to saturation at each stage’s pressure and target temperature. A refrigerated dryer’s cold separator can drain liquid. A desiccant target is a pressure dew point, and regeneration typically exhausts the removed water as vapor. Drain estimates use about 1 kg of water per liter and the entered daily hours.

Find pressure and atmospheric dew points

Pv,out = Pline × wout/(0.621945 + wout) · Pv,atm = Pv,out × Pₐₜₘ/Pline

Invert the saturation equation at each vapor pressure. Below freezing the result is a frost point. Values below −65 °C extrapolate the ice fit. ISO 8573-1 class verification requires measured air quality at the point of use.

Flow labels use dry gas at 101.325 kPa, with 60 °F for SCFM and 0 °C for normal metric flow. See all unit conventions.

Worked examples