500 L Dry Receiver

Check a 500 L dry receiver with a 2 bar pressure band and a short normal-flow surge.

Inputs

View results ↓
Surge and pressure band
NL/min
NL/min
bar(g)
bar(g)
s
Installed tank and cycling
L
NL/min
starts/h

Results

Edit inputs ↑
Receiver pressure band and cycle MIN. TANK 241 LUSABLE AIR 933.7 NLSURGE HOLD 93.37 sSTART RATE 19 starts/h RECEIVER CUT-OUT 8.5 bar(g) CUT-IN 6.5 bar(g) OFF ON INSTALLED SURGE RESERVE 207.5 % 0% 100% REQUIRED 150%
Receiver pressure band and cycle
  • Estimated start frequency exceeds the entered OEM limit.
Minimum tank volume for surge
240.96 L63.656 US gal
Usable air in installed tank
933.75 NL
Installed surge hold time
93.375 s
Estimated starts per hour
19 starts/h
Pump-up at continuous load
72.76 s
Blow-down at continuous load
116.72 s
Operating pressure band
2 bar
Net surge deficit
600 NL/min

Formula and assumptions

Size for the surge

V = t × max(C − S, 0) × Pₐₜₘ/(Pₕᵢ − Pₗₒ)

Demand C and compressor supply S must use the same free-air reference. For U.S. hand calculations use minutes and SCFM to obtain ft³ of tank volume. On the normal metric basis Q is at 0 °C. This calculator converts to the 60 °F free-air basis first, then applies the pressure ratio at that assumed tank temperature.

Check installed storage

Usable free air = installed V × (Pₕᵢ − Pₗₒ)/Pₐₜₘ

Surge hold time divides usable air by net surge demand. With the compressor off, blow-down time uses continuous demand. With the compressor on, pump-up time uses supply minus continuous demand. A dash marks a time that has no finite value under the entered conditions.

Check compressor cycling

Starts/h = 3,600/(pump-up seconds + blow-down seconds)

This simple start/stop estimate assumes constant demand, fixed compressor capacity, and isothermal air. Use the applicable OEM start limit and verify the pressure band and required response at the point of use. Receiver capacity estimates do not specify vessel construction or relief capacity.

Flow labels use dry gas at 101.325 kPa, with 60 °F for SCFM and 0 °C for normal metric flow. See all unit conventions.

Worked examples