Packaging Line Flow Spike

Estimate capacity for a 15-second, 240 SCFM spike in a 10 psi pressure window.

Inputs

View results ↓
Surge and pressure band
SCFM
SCFM
psig
psig
s
Installed tank and cycling
US gal
SCFM
starts/h

Results

Edit inputs ↑
Receiver pressure band and cycle MIN. TANK 357.3 US galUSABLE AIR 21.83 scfSURGE HOLD 10.08 sSTART RATE 73.08 starts/h RECEIVER CUT-OUT 110 psig CUT-IN 100 psig OFF ON INSTALLED SURGE RESERVE 67.17 % 0% 100% REQUIRED 150%
Receiver pressure band and cycle
  • The installed receiver falls short of the specified surge duration.
  • Estimated start frequency exceeds the entered OEM limit.
Minimum tank volume for surge
357.28 US gal1,352.5 L
Usable air in installed tank
21.831 scf
Installed surge hold time
10.076 s
Estimated starts per hour
73.081 starts/h
Pump-up at continuous load
20.152 s
Blow-down at continuous load
29.109 s
Operating pressure band
10 psi
Net surge deficit
130 SCFM

Formula and assumptions

Size for the surge

V = t × max(C − S, 0) × Pₐₜₘ/(Pₕᵢ − Pₗₒ)

Demand C and compressor supply S must use the same free-air reference. For U.S. hand calculations use minutes and SCFM to obtain ft³ of tank volume. On the normal metric basis Q is at 0 °C. This calculator converts to the 60 °F free-air basis first, then applies the pressure ratio at that assumed tank temperature.

Check installed storage

Usable free air = installed V × (Pₕᵢ − Pₗₒ)/Pₐₜₘ

Surge hold time divides usable air by net surge demand. With the compressor off, blow-down time uses continuous demand. With the compressor on, pump-up time uses supply minus continuous demand. A dash marks a time that has no finite value under the entered conditions.

Check compressor cycling

Starts/h = 3,600/(pump-up seconds + blow-down seconds)

This simple start/stop estimate assumes constant demand, fixed compressor capacity, and isothermal air. Use the applicable OEM start limit and verify the pressure band and required response at the point of use. Receiver capacity estimates do not specify vessel construction or relief capacity.

Flow labels use dry gas at 101.325 kPa, with 60 °F for SCFM and 0 °C for normal metric flow. See all unit conventions.

Worked examples