Packaging Line Flow Spike
Estimate capacity for a 15-second, 240 SCFM spike in a 10 psi pressure window.
Inputs
View results ↓Results
Edit inputs ↑- Minimum tank volume for surge
- 357.28 US gal1,352.5 L
- Usable air in installed tank
- 21.831 scf
- Installed surge hold time
- 10.076 s
- Estimated starts per hour
- 73.081 starts/h
- Pump-up at continuous load
- 20.152 s
- Blow-down at continuous load
- 29.109 s
- Operating pressure band
- 10 psi
- Net surge deficit
- 130 SCFM
Formula and assumptions
Size for the surge
V = t × max(C − S, 0) × Pₐₜₘ/(Pₕᵢ − Pₗₒ)
Demand C and compressor supply S must use the same free-air reference. For U.S. hand calculations use minutes and SCFM to obtain ft³ of tank volume. On the normal metric basis Q is at 0 °C. This calculator converts to the 60 °F free-air basis first, then applies the pressure ratio at that assumed tank temperature.
Check installed storage
Usable free air = installed V × (Pₕᵢ − Pₗₒ)/Pₐₜₘ
Surge hold time divides usable air by net surge demand. With the compressor off, blow-down time uses continuous demand. With the compressor on, pump-up time uses supply minus continuous demand. A dash marks a time that has no finite value under the entered conditions.
Check compressor cycling
Starts/h = 3,600/(pump-up seconds + blow-down seconds)
This simple start/stop estimate assumes constant demand, fixed compressor capacity, and isothermal air. Use the applicable OEM start limit and verify the pressure band and required response at the point of use. Receiver capacity estimates do not specify vessel construction or relief capacity.
Flow labels use dry gas at 101.325 kPa, with 60 °F for SCFM and 0 °C for normal metric flow. See all unit conventions.
Worked examples
-
Baghouse Pulse Reserve
Store enough air for a one-minute draw while the compressor supplies part of the surge.
-
Compressor-Off Air Buffer
Supply a 20-second demand entirely from the receiver while the compressor is off.
-
Small Shop Compressor Cycling
Check a 60-gallon receiver paired with a 17 SCFM start/stop compressor.
-
Packaging Line Flow Spike
Estimate capacity for a 15-second, 240 SCFM spike in a 10 psi pressure window.
-
500 L Dry Receiver
Check a 500 L dry receiver with a 2 bar pressure band and a short normal-flow surge.
-
Supply Covers the Surge
Explore a demand spike below available compressor flow.
-
No Refill Margin at Base Load
Check a receiver where the continuous load already uses all available compressor capacity.