Compact Assembly Clamp

Check a short-stroke pneumatic clamp with a low cycle rate and an 80 lbf tool load.

Inputs

View results ↓
Cylinder and supply
in
in
psig
%
in
cycles/min
Dynamic load check
lbf

Results

Edit inputs ↑
Double-acting cylinder cutaway EXTEND 116.6 lbfRETRACT 103.7 lbfAIR USE 0.1415 SCFMPRESS. RATIO 6.103 CAP END ROD END STROKE 1.5 in PUSH DYNAMIC LOAD RATIO 68.59 % 0% 75% SCREEN 100% FORCE
Double-acting cylinder cutaway
Extend force
116.63 lbf
Retract force
103.67 lbf
Free-air consumption
0.14148 SCFM
Compression ratio
6.1034
Bore for 75% load
1.4345 in
Selected stroke load ratio
68.592 %
Free air per cycle
0.017685 scf
Cap-end piston area
1.7671 in²
Rod-side annular area
1.5708 in²

Formula and assumptions

Push, pull, and bore

Aₚ = πD²/4 · Aᵣ = πd²/4 · Fpush = ηP Aₚ · Fpull = ηP(Aₚ − Aᵣ)

Use supply gauge pressure P at the cylinder, assuming the exhaust chamber is at atmospheric pressure. Bore sizing solves the selected force equation at 75% utilization with the entered rod diameter held fixed. Choose a bore larger than the rod and verify the OEM’s bearing loads, buckling limits, and stroke allowances.

Free air per minute

Q = (2Aₚ − Aᵣ) × stroke × cycles/min × (P + Pₐₜₘ)/Pₐₜₘ

A cycle is one full extension and retraction. The compression factor converts swept volume to free air at the same reference temperature. Add separate allowances for tubing, dead volumes, valve losses, and leakage.

Load ratio

Load ratio = required applied force ÷ available force on the selected stroke

Above 75% the calculator flags the dynamic margin. Use the lowest pressure expected during motion and include acceleration and tooling forces in the applied load estimate.

Flow labels use dry gas at 101.325 kPa, with 60 °F for SCFM and 0 °C for normal metric flow. See all unit conventions.

Worked examples