High-Speed Sorting Cylinder

Estimate air demand for a small reject gate extending and retracting 85 times per minute.

Inputs

View results ↓
Cylinder and supply
in
in
psig
%
in
cycles/min
Dynamic load check
lbf

Results

Edit inputs ↑
Double-acting cylinder cutaway EXTEND 77.31 lbfRETRACT 70.35 lbfAIR USE 1.993 SCFMPRESS. RATIO 5.763 CAP END ROD END STROKE 3 in PUSH DYNAMIC LOAD RATIO 38.8 % 0% 75% SCREEN 100% FORCE
Double-acting cylinder cutaway
Extend force
77.313 lbf
Retract force
70.354 lbf
Free-air consumption
1.9934 SCFM
Compression ratio
5.7632
Bore for 75% load
0.89911 in
Selected stroke load ratio
38.803 %
Free air per cycle
0.023452 scf
Cap-end piston area
1.2272 in²
Rod-side annular area
1.1167 in²

Formula and assumptions

Push, pull, and bore

Aₚ = πD²/4 · Aᵣ = πd²/4 · Fpush = ηP Aₚ · Fpull = ηP(Aₚ − Aᵣ)

Use supply gauge pressure P at the cylinder, assuming the exhaust chamber is at atmospheric pressure. Bore sizing solves the selected force equation at 75% utilization with the entered rod diameter held fixed. Choose a bore larger than the rod and verify the OEM’s bearing loads, buckling limits, and stroke allowances.

Free air per minute

Q = (2Aₚ − Aᵣ) × stroke × cycles/min × (P + Pₐₜₘ)/Pₐₜₘ

A cycle is one full extension and retraction. The compression factor converts swept volume to free air at the same reference temperature. Add separate allowances for tubing, dead volumes, valve losses, and leakage.

Load ratio

Load ratio = required applied force ÷ available force on the selected stroke

Above 75% the calculator flags the dynamic margin. Use the lowest pressure expected during motion and include acceleration and tooling forces in the applied load estimate.

Flow labels use dry gas at 101.325 kPa, with 60 °F for SCFM and 0 °C for normal metric flow. See all unit conventions.

Worked examples