This hot tub uses a sanitizer that adds no stabilizer. Warm water is important to the saturation calculation. Check spa sanitizer separately and follow the spa manufacturer’s guidance.
7.6 measured pH − 7.429 saturation pH = +0.17 LSI. The full-precision result falls in the balanced band.
The LSI balance band spans −0.30 through +0.30. It describes calcium carbonate behavior. Check sanitizer and pH separately with your test kit.
Calcite SI uses a separate activity estimate with a sodium-chloride-equivalent TDS and approximate free calcium. A laboratory mineral profile can change this estimate.
Common questions
Does this 102°F example need a cyanurate deduction?
With measured CYA set to zero, the CYA alkalinity contribution is zero. Borates would still be corrected if present.
Why can the two saturation estimates disagree slightly in spa water?
LSI uses empirical temperature and dissolved-solids factors. The separate calcite estimate approximates ion activities and temperature-dependent equilibrium.
7.6 measured pH − 7.429 saturation pH = +0.17 LSI. The full-precision result falls in the balanced band.
An LSI result describes mineral balance. Verify chlorine, pH and alkalinity with a pool test kit before deciding on any adjustment. Read the product label, wear the required protection and keep swimmers out during treatment. Never mix pool chemicals or chlorine types, and never add acid and chlorine together. Verify readings with a pool or spa test kit before adding chemicals and retest after circulation and before use.