Worked example

LSI With 50 ppm Borates and 50 ppm CYA

The water test reports borate as elemental boron. At the higher pH, more of that buffer contributes to TA. The tool shows the borate and CYA deductions separately.

Jump to results

Example readings

Water test
°F
ppm
ppm
Dissolved minerals and buffers
ppm
Use TDS, including salt where applicable.
ppm
ppm
Use a reading reported as B.

Results

Estimate

Langelier saturation index
+0.44
Scale-forming
Calcite saturation index
+0.53
Corrected alkalinity
51.2 ppm
Saturation pH
7.66
CYA contribution
18.2 ppm
Borate contribution
15.6 ppm
Langelier balance scale
+0.44 LSIScale-forming−1.20−0.300+0.30+1.20CorrosiveBalancedScale-forming

Export & share

Worked calculation

  1. 85 ppm measured TA − (50 × 0.364) − (50 × 0.313) = 51.16 ppm corrected alkalinity.
  2. 9.3 + 0.22 (TDS) + 1.991 (temperature) − 2.144 (calcium) − 1.709 (alkalinity) = 7.658 saturation pH.
  3. 8.1 measured pH − 7.658 saturation pH = +0.44 LSI. The full-precision result falls in the scale-forming band.
  • The LSI balance band spans −0.30 through +0.30. It describes calcium carbonate behavior. Check sanitizer and pH separately with your test kit.
  • Calcite SI uses a separate activity estimate with a sodium-chloride-equivalent TDS and approximate free calcium. A laboratory mineral profile can change this estimate.

Common questions

What is the difference between ppm boron and ppm boric acid?

They report different chemical masses. This field expects elemental boron, so use the test manufacturer’s reporting basis and conversion.

Why is the borate correction larger at pH 8.1 than at pH 7.4?

A higher pH increases the proportion of deprotonated borate. More of the same total boron contributes to measured alkalinity.

Method and safety references