Worked example

LSI for an 18,000-Gallon Plaster Pool at pH 7.6 and 80°F

A plaster-pool owner has a pH of 7.6 and measured alkalinity of 80 ppm. The model first removes cyanurate alkalinity, then compares measured pH with saturation pH. Pool volume is context for this snapshot and matters if a dose is planned later.

Jump to results

Example readings

Water test
°F
ppm
ppm
Dissolved minerals and buffers
ppm
Use TDS, including salt where applicable.
ppm
ppm
Use a reading reported as B.

Results

Estimate

Langelier saturation index
-0.06
Balanced
Calcite saturation index
+0.07
Corrected alkalinity
67 ppm
Saturation pH
7.66
CYA contribution
13 ppm
Borate contribution
0 ppm
Langelier balance scale
-0.06 LSIBalanced−1.20−0.300+0.30+1.20CorrosiveBalancedScale-forming

Export & share

Worked calculation

  1. 80 ppm measured TA − (40 × 0.324) − (0 × 0.104) = 67.04 ppm corrected alkalinity.
  2. 9.3 + 0.208 (TDS) + 2.054 (temperature) − 2.077 (calcium) − 1.826 (alkalinity) = 7.658 saturation pH.
  3. 7.6 measured pH − 7.658 saturation pH = -0.06 LSI. The full-precision result falls in the balanced band.
  • The LSI balance band spans −0.30 through +0.30. It describes calcium carbonate behavior. Check sanitizer and pH separately with your test kit.
  • Calcite SI uses a separate activity estimate with a sodium-chloride-equivalent TDS and approximate free calcium. A laboratory mineral profile can change this estimate.

Common questions

Why does the 18,000-gallon size stay out of the LSI formula?

LSI uses temperature and concentrations. A larger pool with the same readings has the same calculated index but needs more product for the same concentration change.

What does 40 ppm CYA do to the 80 ppm alkalinity reading?

At pH 7.6 it accounts for roughly 13 ppm of alkalinity in this model, leaving about 67 ppm to use in the saturation formula.