This model treats dry acid as 93.2% sodium bisulfate. Weigh the granules and use the manufacturer’s stated product strength and handling directions for the real adjustment.
Holding dissolved carbon dioxide exchange at zero, moving from pH 7.9 to 7.5 changes the initial buffer requirement by -0.0875 meq/L.
-0.0875 meq/L ÷ -1 effective equivalents per mole = 0.08753 mmol/L of active product.
Scale by 45,425 L, molecular weight and label strength. The estimate is 512.18 g of product.
The pH estimate uses a short-term carbonate buffer model near room temperature, including CYA and borates. Aeration and carbon dioxide exchange can move the measured pH afterward.
Use the label to plan staged additions. If its instructions call for predilution, add acid slowly to water, never pour water into acid. Never mix pool chemicals or apply acid and chlorine together.
Common questions
What purity is assumed for the sodium bisulfate calculation?
The dry acid preset uses 93.2% sodium bisulfate by mass. A different formulation changes the product weight required.
What dissolved material does dry acid introduce alongside the pH change?
Sodium bisulfate adds sulfate. Ask the equipment or surface manufacturer about any restrictions for repeated use.
Holding dissolved carbon dioxide exchange at zero, moving from pH 7.9 to 7.5 changes the initial buffer requirement by -0.0875 meq/L.
-0.0875 meq/L ÷ -1 effective equivalents per mole = 0.08753 mmol/L of active product.
Scale by 45,425 L, molecular weight and label strength. The estimate is 512.18 g of product.
Follow the product label. When it calls for predilution, add acid slowly to water and never pour water into acid. Read the product label, wear the required protection and keep swimmers out during treatment. Never mix pool chemicals or chlorine types, and never add acid and chlorine together. Verify readings with a pool or spa test kit before adding chemicals and retest after circulation and before use.