Worked example

Dry Acid for a 12,000-Gallon Pool at pH 7.9

This model treats dry acid as 93.2% sodium bisulfate. Weigh the granules and use the manufacturer’s stated product strength and handling directions for the real adjustment.

Jump to results

Example readings

Current water test
US gal
ppm
ppm
ppm
Desired adjustment

Results

Estimate

Dry product estimate
18.07 oz wt
Estimated immediate pH
7.5
Estimated total alkalinity
80.6 ppm
Modeled pH change
-0.40
Modeled TA change
-4.4 ppm
pH and alkalinity before and after
pH7.9 → 7.56.88.3Total alkalinity85 → 80.6 ppm0150

Export & share

Worked calculation

  1. Holding dissolved carbon dioxide exchange at zero, moving from pH 7.9 to 7.5 changes the initial buffer requirement by -0.0875 meq/L.
  2. -0.0875 meq/L ÷ -1 effective equivalents per mole = 0.08753 mmol/L of active product.
  3. Scale by 45,425 L, molecular weight and label strength. The estimate is 512.18 g of product.
  • The pH estimate uses a short-term carbonate buffer model near room temperature, including CYA and borates. Aeration and carbon dioxide exchange can move the measured pH afterward.
  • Use the label to plan staged additions. If its instructions call for predilution, add acid slowly to water, never pour water into acid. Never mix pool chemicals or apply acid and chlorine together.

Common questions

What purity is assumed for the sodium bisulfate calculation?

The dry acid preset uses 93.2% sodium bisulfate by mass. A different formulation changes the product weight required.

What dissolved material does dry acid introduce alongside the pH change?

Sodium bisulfate adds sulfate. Ask the equipment or surface manufacturer about any restrictions for repeated use.

Method and safety references