Worked example

Borax to Raise pH From 7.1 to 7.4 in 14,000 Gallons

The example assumes borax decahydrate rather than a differently hydrated borate. Borax adds both alkalinity and boron. Boron accumulation matters if you plan repeated additions.

Jump to results

Example readings

Current water test
US gal
ppm
ppm
ppm
Desired adjustment

Results

Estimate

Dry product estimate
61.58 oz wt
Estimated immediate pH
7.4
Estimated total alkalinity
93.6 ppm
Modeled pH change
+0.30
Modeled TA change
+8.6 ppm
pH and alkalinity before and after
pH7.1 → 7.46.88.3Total alkalinity85 → 93.6 ppm0150

Export & share

Worked calculation

  1. Holding dissolved carbon dioxide exchange at zero, moving from pH 7.1 to 7.4 changes the initial buffer requirement by 0.1678 meq/L.
  2. 0.1678 meq/L ÷ 1.9431 effective equivalents per mole = 0.08638 mmol/L of active product.
  3. Scale by 52,996 L, molecular weight and label strength. The estimate is 1,745.79 g of product.
  • The pH estimate uses a short-term carbonate buffer model near room temperature, including CYA and borates. Aeration and carbon dioxide exchange can move the measured pH afterward.
  • Use the label to plan staged additions. If its instructions call for predilution, add acid slowly to water, never pour water into acid. Never mix pool chemicals or apply acid and chlorine together.

Common questions

Can I use the same number for borax pentahydrate?

Hydration changes molecular weight and dose per gram. The calculator uses decahydrate; use the actual product’s instructions.

Where would added boron show up in a later balance check?

If you measure boron, its buffer contribution can be included in the LSI calculation. Enter the test value on an elemental-boron basis.

Method and safety references