Worked example

Lower Pool pH From 7.8 to 7.4 With 31.45% Muriatic Acid

The same pH drop takes more acid when water has more available buffering. This example estimates the immediate change with 90 ppm measured TA, then shows where TA would land in the model.

Jump to results

Example readings

Current water test
US gal
ppm
ppm
ppm
Desired adjustment

Results

Estimate

Liquid product estimate
14.91 fl oz
Estimated immediate pH
7.4
Estimated total alkalinity
84.2 ppm
Modeled pH change
-0.40
Modeled TA change
-5.8 ppm
pH and alkalinity before and after
pH7.8 → 7.46.88.3Total alkalinity90 → 84.2 ppm0150

Export & share

Worked calculation

  1. Holding dissolved carbon dioxide exchange at zero, moving from pH 7.8 to 7.4 changes the initial buffer requirement by -0.1166 meq/L.
  2. -0.1166 meq/L ÷ -1 effective equivalents per mole = 0.11657 mmol/L of active product.
  3. Scale by 37,854 L, molecular weight and label strength. The estimate is 511.59 g of product, or 441.02 mL at 1.16 g/mL.
  • The pH estimate uses a short-term carbonate buffer model near room temperature, including CYA and borates. Aeration and carbon dioxide exchange can move the measured pH afterward.
  • Use the label to plan staged additions. If its instructions call for predilution, add acid slowly to water, never pour water into acid. Never mix pool chemicals or apply acid and chlorine together.

Common questions

Why can my acid demand test differ from the 7.8 to 7.4 estimate?

The calculator uses a simplified carbonate buffer. An acid demand test responds to buffering in the actual water sample. Use the test and label to guide staged additions.

What if pH rises the day after an acid addition?

Aeration can drive carbon dioxide out of the water and bring pH back up. Retest and check TA before planning another addition.