PowerConvLab · Design worksheet
60 V MOSFET with measured overshoot
Device limit exceeded · The device heat total excludes gate-drive power. Recovery heat may be split between devices.
Inputs
- Switched drain voltage
- 48 V
- Conducting current
- 6 A
- On duty
- 31 %
- Switching frequency
- 330 kHz
- Converter output power
- 95 W
- Additional drain overshoot
- 16 V
- MOSFET drain rating
- 60 V
- Junction temperature input
- Enter operating junction
- Operating junction
- 100 °C
- Junction ceiling
- 150 °C
- Cold Rᴅₛ₍ₒₙ₎
- 8 mΩ
- Hot resistance factor
- 1.55 ×
- Turn-on overlap
- 12 ns
- Turn-off overlap
- 15 ns
- Total gate charge
- 42 nC
- Gate drive swing
- 10 V
- Total gate loop resistance
- 5 Ω
- Output capacitance model
- Charge Qoss (linear estimate)
- Output charge Qₒₛₛ
- 31 nC
- Reverse-recovery charge
- 22 nC
- Body-diode drop
- 0.85 V
- Total dead time per cycle
- 60 ns
Calculated results
- Hot on-resistance
- 12.4 mΩ
- Channel conduction
- 0.138384 W
- Switching overlap
- 1.28304 W
- Output capacitance
- 0.24552 W
- Reverse recovery
- 0.34848 W
- Dead-time diode conduction
- 0.10098 W
- Modeled device-side loss
- 2.1164 W
- Gate-drive supply power
- 0.1386 W
- Combined modeled loss
- 2.255 W
- Initial gate drive current estimate
- 2 A
- Efficiency penalty vs. ideal
- 2.31865 pp
- Efficiency with these losses only
- 97.6813 %
- Drain stress with overshoot
- 64 V
- Drain headroom
- -4 V
- Operating junction temperature
- 100 °C
- Junction headroom
- 50 °C