PowerConvLab · Design worksheet
Inductor Core Flux, Air Gap & Loss Calculator
Flux headroom available · Saturation uses the selected threshold. Check flux and inductance at operating temperature.
Inputs
- Winding turns
- 14 turns
- Target inductance
- 22 µH
- Effective core area
- 70 mm²
- Magnetic path length
- 52 mm
- Effective core volume
- 3.64 cm³
- Peak current magnitude
- 8 A
- AC peak-to-peak current
- 2.4 A
- Switching frequency
- 150 kHz
- Core material
- N87 ferrite · 390 mT
Calculated results
- Peak flux density
- 179.592 mT
- Minimum flux density
- 125.714 mT
- AC flux swing (peak-to-peak)
- 53.8776 mT
- AC flux amplitude
- 26.9388 mT
- Midpoint DC current
- 6.8 A
- DC magnetizing field
- 1,830.77 A/m
- Material saturation threshold
- 390 mT
- Peak-flux headroom
- 210.408 mT
- Peak-flux headroom
- 53.9508 %
- Relative permeability used
- 2,200
- Equivalent discrete air gap
- 0.760048 mm
- Estimated ungapped inductance
- 729.429 µH
- Steinmetz coefficient k
- 1.7592
- Steinmetz frequency exponent α
- 1.35893
- Steinmetz flux exponent β
- 2.09727
- Modeled magnetic loss density
- 9,712.63 W/m³
- Modeled core loss
- 0.035354 W