Heatsink & Junction Temperature Calculator

Follow heat from silicon to ambient and budget the heatsink resistance for a MOSFET or linear regulator.

Design inputs

Dissipation
Thermal path
View live readout ↑

Live readout

Edit inputs
Junction Tⱼ
104.9 °C
Tⱼ headroom
20.15 °C
Max. sink Rθ
7.239 °C/W
Power budget
12.03 W
Thermal resistance ladder Thermal resistance ladder 9 W heat Junction105 °CCase94.1 °CSink90 °CAmbient45 °CHeat flow →RθJC1.2 °C/WRθCS0.45 °C/WRθSA5 °C/W
Temperatures step down along the main heatsink path in proportion to dissipated power and each thermal resistance.
Junction headroom available

Steady-state series path from the junction through the heatsink to ambient.

Junction / ceiling104.9 °C / 125 °C

Result breakdown
Dissipated power9 W
Ambient temperature45 °C
Heatsink temperature90 °C
Case temperature94.05 °C
Junction temperature104.85 °C
Junction temperature headroom20.15 °C
Total series resistance6.65 °C/W
Maximum allowable sink resistance7.23889 °C/W
Maximum allowable power at ambient12.0301 W
Maximum allowable ambient at this power65.15 °C

Formulas and assumptions

Heat source

Pd = (Vin − Vout) · Iout + Vin · Iq

Use measured or modeled dissipation directly for a semiconductor. In LDO mode, voltage dropped across the pass element and quiescent current both add heat.

Resistance ladder

Tj = Ta + Pd · (RθJC + RθCS + RθSA)

The sink rises above ambient by Pd·RθSA. Add Pd·RθCS to reach the case and Pd·RθJC to reach the silicon. This model uses a single, steady-state path.

Derating

RθSA,max = (Tj,max − Ta)/Pd − RθJC − RθCS

A negative maximum means the junction limit cannot be met with any nonnegative sink resistance at that power. Verify actual case, interface and airflow conditions. For pulses or parallel board heat paths, use the relevant impedance network.