Temperatures step down along the main heatsink path in proportion to dissipated power and each thermal resistance.
Junction headroom available
Steady-state series path from the junction through the heatsink to ambient.
Junction / ceiling104.9 °C / 125 °C
Result breakdown
Dissipated power
9 W
Ambient temperature
45 °C
Heatsink temperature
90 °C
Case temperature
94.05 °C
Junction temperature
104.85 °C
Junction temperature headroom
20.15 °C
Total series resistance
6.65 °C/W
Maximum allowable sink resistance
7.23889 °C/W
Maximum allowable power at ambient
12.0301 W
Maximum allowable ambient at this power
65.15 °C
Formulas and assumptions
Heat source
Pd = (Vin − Vout) · Iout + Vin · Iq
Use measured or modeled dissipation directly for a semiconductor. In LDO mode, voltage dropped across the pass element and quiescent current both add heat.
Resistance ladder
Tj = Ta + Pd · (RθJC + RθCS + RθSA)
The sink rises above ambient by Pd·RθSA. Add Pd·RθCS to reach the case and Pd·RθJC to reach the silicon. This model uses a single, steady-state path.
Derating
RθSA,max = (Tj,max − Ta)/Pd − RθJC − RθCS
A negative maximum means the junction limit cannot be met with any nonnegative sink resistance at that power. Verify actual case, interface and airflow conditions. For pulses or parallel board heat paths, use the relevant impedance network.
{"tool":{"id":"thermal","groups":[{"title":"Dissipation","fields":[{"key":"mode","label":"Power input mode","value":"direct","options":[["direct","Enter dissipated power"],["ldo","Calculate from an LDO"]]},{"key":"power","label":"Dissipated power","value":9,"unit":"W","help":"","when":["mode","direct"]},{"key":"vin","label":"LDO input voltage","value":12,"unit":"V","help":"","when":["mode","ldo"]},{"key":"vout","label":"LDO output voltage","value":5,"unit":"V","help":"","when":["mode","ldo"]},{"key":"iout","label":"LDO output current","value":0.6,"unit":"A","help":"","when":["mode","ldo"]},{"key":"iq","label":"LDO quiescent current","value":2,"unit":"mA","help":"","when":["mode","ldo"]}]},{"title":"Thermal path","fields":[{"key":"ambient","label":"Maximum ambient","value":45,"unit":"temperature","help":""},{"key":"ceiling","label":"Junction ceiling","value":125,"unit":"temperature","help":""},{"key":"jc","label":"Junction → case RθJC","value":1.2,"unit":"theta","help":""},{"key":"cs","label":"Case → sink RθCS","value":0.45,"unit":"theta","help":""},{"key":"sa","label":"Sink → ambient RθSA","value":5,"unit":"theta","help":""}]}],"cards":[["tj","Junction Tⱼ"],["margin","Tⱼ headroom"],["maxSa","Max. sink Rθ"],["maxPower","Power budget"]],"rows":[["power","Dissipated power","W"],["ambient","Ambient temperature","temperature"],["ts","Heatsink temperature","temperature"],["tc","Case temperature","temperature"],["tj","Junction temperature","temperature"],["margin","Junction temperature headroom","rise"],["totalR","Total series resistance","theta"],["maxSa","Maximum allowable sink resistance","theta","Not applicable at zero dissipation"],["maxPower","Maximum allowable power at ambient","W","No finite limit in ideal zero-resistance model"],["maxAmbient","Maximum allowable ambient at this power","temperature"]],"caption":"Temperatures step down along the main heatsink path in proportion to dissipated power and each thermal resistance."},"title":"Heatsink & Junction Temperature Calculator","slug":"heatsink-junction-temperature-calculator","defaults":{"mode":"direct","power":9,"vin":12,"vout":5,"iout":0.6,"iq":2,"ambient":45,"ceiling":125,"jc":1.2,"cs":0.45,"sa":5}}
PowerConvLab · Design worksheet
Heatsink & Junction Temperature Calculator
Junction headroom available · Steady-state series path from the junction through the heatsink to ambient.