PowerConvLab · Design worksheet
Bridge Rectifier Bulk Capacitor & Hold-Up Calculator
Bus design headroom available · Voltage headroom includes the entered surge allowance. Check inrush, capacitor tolerance and ripple-current rating separately.
Inputs
- Nominal AC input
- 230 V RMS
- Low-line input mode
- Apply line tolerance
- Low-line reduction
- 15 %
- High-line increase
- 10 %
- Line frequency
- 50 Hz
- Rectifier topology
- Full-wave bridge
- Drop per conducting diode
- 0.95 V
- Downstream output power
- 90 W
- Downstream efficiency
- 88 %
- Bus ripple target
- 28 V
- Minimum DC bus
- 180 V
- Hold-up time unit
- Milliseconds
- Required hold-up time
- 20 ms
- Installed bulk capacitance
- 0 µF
- Capacitor voltage rating
- 450 V
- Additional surge allowance
- 0 V
Calculated results
- Low-line input
- 195.5 V RMS
- Low-line rectified peak
- 274.579 V
- Nominal rectified peak
- 323.369 V
- High-line rectified peak
- 355.896 V
- High-line stress with surge allowance
- 355.896 V
- Constant power from bus
- 102.273 W
- Valley at ripple target
- 246.579 V
- Estimated operating valley
- 251.133 V
- Estimated peak-to-peak ripple
- 23.4455 V
- Discharge interval at ripple target
- 8.55506 ms
- Capacitance for ripple
- 119.918 µF
- Capacitance for hold-up
- 144.041 µF
- Governing capacitance
- 144.041 µF
- Governing requirement
- Hold-up
- Capacitance used in readout
- 144.041 µF
- Estimated hold-up from valley
- 21.5963 ms
- Hold-up headroom
- 1.59628 ms
- Bus ripple headroom
- 4.55446 V
- High-line voltage headroom
- 94.104 V