Zero-dissipation thermal boundary

Check the quiescent boundary when the dissipated heat load is zero.

Design inputs

Dissipation
Thermal path
View live readout ↑

Live readout

Edit inputs
Junction Tⱼ
65 °C
Tⱼ headroom
30 °C
Max. sink Rθ
—
Power budget
2.326 W
Thermal resistance ladder Thermal resistance ladder 0 W heat Junction65 °CCase65 °CSink65 °CAmbient65 °CHeat flow →RθJC1.5 °C/WRθCS0.4 °C/WRθSA11 °C/W
Temperatures step down along the main heatsink path in proportion to dissipated power and each thermal resistance.
Junction headroom available

At zero dissipation, the heatsink resistance does not set junction rise.

Junction / ceiling65 °C / 95 °C

Result breakdown
Dissipated power0 W
Ambient temperature65 °C
Heatsink temperature65 °C
Case temperature65 °C
Junction temperature65 °C
Junction temperature headroom30 °C
Total series resistance12.9 °C/W
Maximum allowable sink resistanceNot applicable at zero dissipation
Maximum allowable power at ambient2.32558 W
Maximum allowable ambient at this power95 °C

Worked calculation

Tj = 65 °C + 0 W × 12.9 °C/W = 65 °C

Every node equals ambient. The allowable power at this ambient still reflects the entered resistance chain.

Heat source

Pd = (Vin − Vout) · Iout + Vin · Iq

Use measured or modeled dissipation directly for a semiconductor. In LDO mode, voltage dropped across the pass element and quiescent current both add heat.

Resistance ladder

Tj = Ta + Pd · (RθJC + RθCS + RθSA)

The sink rises above ambient by Pd·RθSA. Add Pd·RθCS to reach the case and Pd·RθJC to reach the silicon. This model uses a single, steady-state path.

Derating

RθSA,max = (Tj,max − Ta)/Pd − RθJC − RθCS

A negative maximum means the junction limit cannot be met with any nonnegative sink resistance at that power. Verify actual case, interface and airflow conditions. For pulses or parallel board heat paths, use the relevant impedance network.