Methodology
The calculators estimate steady-state electrical and thermal operating points. Limits compare the entered targets and component ratings with those estimates.
Reading the margins
A margin at zero means the model lands on the entered limit. Negative headroom means the limit is exceeded. A result within the model limits still requires component tolerance, operating corners, transient behavior and hardware verification. For mains designs, verify insulation, creepage, inrush and surge separately.
Temperatures are stored in °C. Absolute temperatures use the °F offset in imperial display; rises and thermal resistances convert by scale alone. JSON exports preserve model units. CSV exports use the selected display units.
SMPS Inductor & Ripple
Open calculator ↗Duty & inductor
Veff = η · Vin | L = Von · D / (fs · ΔIL)
Efficiency is represented by an effective input voltage ahead of an ideal switching stage. Duty is Vout/Veff for buck, 1 − Veff/Vout for boost, and Vout/(Veff + Vout) for the inverting topology. Output magnitude is positive for all three cases.
Boundary & current
Icrit = (ΔIL,CCM / 2) · k | k = 1 (buck), 1 − D (boost / inverting)
At the boundary, the valley inductor current is zero. Below it, the model solves on-time and off-time from the two current slopes and load charge balance. For CCM the RMS value is √(Iavg² + ΔIL²/12).
Ripple budget
ΔVpp ≈ Qpositive / Cout + ESR · ΔIcap
Positive capacitor current is integrated over the waveform. For a CCM buck this yields ΔIL/(8·fs·Cout). CCM boost and inverting stages reduce to Iout·D/(fs·Cout) when coil current during discharge stays above load current. Use effective capacitance under DC bias.
Technical references
Flyback & RCD Clamp
Open calculator ↗Turns ratio & duty
Np/Ns = VOR / (Vout + Vf) | D = VOR / (Vin,min + VOR)
The reflected voltage must fit the maximum low-line duty. Low-line peak is (Pout/η)/(Vin,min·D·(1 − Krp/2)). Then Lm = Vin,min·D/(fs·Krp·Ipk).
Winding currents
Irms = √[tfrac · (Ipk² + Ipk·Ivalley + Ivalley²)/3]
Primary and secondary RMS values use their conduction intervals. The secondary waveform uses primary-referred magnetizing current scaled by Np/Ns. At high line the model permits a DCM interval. Winding parasitics and loss allocation require a transformer design check.
Leakage clamp
Pclamp = ½ · Llk · Ipk² · fs · Vclamp / (Vclamp − VOR)
Use the highest modeled primary peak. With leakage, the drain screen uses Vin,max + Vclamp + ΔVclamp/2 and requires the clamp valley to remain above VOR. With zero leakage the model uses Vin,max + VOR. R is Vclamp²/Pclamp and C is approximated as Vclamp/(R·fs·ΔVclamp). Allow headroom for leakage tolerance and residual ringing.
Technical references
MOSFET Loss Budget
Open calculator ↗Channel & hard switching
Pcond = D · I² · R25 · mt | Psw = ½ · VDS · I · (tr + tf) · fs
Use the conducting current during the on interval and a datasheet hot-resistance factor. The overlap term assumes one turn-on and one turn-off per period with the stated voltage and current.
Gate & capacitance
Pgate = Qg · VGS · fs | Poutput cap = Eoss · fs
Direct datasheet Eoss at the bus voltage is preferred for nonlinear output capacitance. Qoss mode approximates Eoss as ½·VDS·Qoss and Coss mode uses ½·Coss·VDS². Initial gate current is VGS/Rloop.
Commutation & efficiency
Prr ≈ Qrr · VDS · fs | Pdiode ≈ VSD · I · tdead · fs
Use one recovery event per period and enter total diode conduction time per cycle. Penalty is 100·Ploss/(Pout + Ploss) percentage points relative to lossless conversion. Avoid adding these terms again if using measured switching energy.
Junction estimate
Tj = Ta + Pdevice · RθJA
Use the effective resistance for the board and cooling path. The estimate holds the entered hot resistance factor constant. Check the datasheet factor at the resulting junction temperature and account for temperature-dependent feedback separately.
Technical references
PCB Copper Trace Width
Open calculator ↗IPC-2221 fit
I = k · ΔT^0.44 · A^0.725 | A in mil²
Use k = 0.048 for external copper and 0.024 for internal copper. Divide the solved area by finished foil thickness for minimum width. Reversing the fit with an installed width estimates actual rise. One ounce per square foot is approximated as 35 µm.
Hot resistance
R = ρ20 · [1 + 0.00393 · (Tcu − 20 °C)] · ℓ / A
Tcu is ambient plus modeled rise and ρ20 is 1.724 × 10⁻⁸ Ω·m. Voltage drop is I·R and dissipation is I²·R. Use RMS current for heating and the current of interest for the voltage-drop estimate.
IPC-2152 context
Check stackup, nearby copper and heat spreading
This screening fit uses IPC-2221 chart constants. IPC-2152 gives separate current-carrying guidance including the effects of board geometry and nearby planes. Check adjacent traces, via bottlenecks, finished copper tolerance and enclosure conditions.
Technical references
Heatsink Thermal Chain
Open calculator ↗Heat source
Pd = (Vin − Vout) · Iout + Vin · Iq
Use measured or modeled dissipation directly for a semiconductor. In LDO mode, voltage dropped across the pass element and quiescent current both add heat.
Resistance ladder
Tj = Ta + Pd · (RθJC + RθCS + RθSA)
The sink rises above ambient by Pd·RθSA. Add Pd·RθCS to reach the case and Pd·RθJC to reach the silicon. This model uses a single, steady-state path.
Derating
RθSA,max = (Tj,max − Ta)/Pd − RθJC − RθCS
A negative maximum means the junction limit cannot be met with any nonnegative sink resistance at that power. Verify actual case, interface and airflow conditions. For pulses or parallel board heat paths, use the relevant impedance network.
Technical references
RC Snubber & Ringing
Open calculator ↗Two captures
Cpar = Ctest / [(f₀/f₁)² − 1] | Lpar = 1 / [(2πf₀)²·Cpar]
Measure the same ringing mode with and without a known parallel test capacitor. Aim for roughly half the original frequency. Nearly equal readings amplify measurement error. Using an installed resistor during the measurement shifts the result.
RC starting point
Z₀ = √(Lpar/Cpar) | Cs = multiplier · Cpar
Start with Rs = Z₀ and Cs = 3·Cpar. Z₀/(2ζ) uses the parallel-resistor approximation at the ringing frequency. The plotted target is illustrative. Component placement and the measured ring-down determine the final values.
Resistor load
Psnub ≈ Cs · Vstep² · fs
This assumes charge and discharge through the resistor each cycle. Compare twice the estimated power to the continuous rating and check repetitive pulse energy separately.
Technical references
Bridge Bulk Cap & Hold-Up
Open calculator ↗Rectified peaks
Vpk,min = √2 · Vac,min − n · Vf | n = 2 (bridge), 1 (half wave)
Full-wave recharge events occur twice per mains cycle. Half-wave recharge occurs once. Under the ideal source model, recharge begins when the rising rectified sine crosses the falling bus.
Ripple & outage energy
Cripple = 2·Pin·tdis/(Vpk,min² − Vvalley²) | Chold = 2·Pin·thold/(Vvalley² − Vmin²)
Vvalley is the low-line peak minus target ripple. Sizing hold-up from that target valley is conservative. For the selected capacitance, the readout solves the modeled crossing and calculates available hold-up from its operating valley.
Hardware checks
Vheadroom = Vrated − (Vpk,high + Vsurge)
This margin covers the steady high-line crest plus the entered surge allowance. Verify surge waveform, ripple-current rating, tolerance and useful life against the actual capacitor. A real bridge requires inrush limiting, source-impedance and charge-pulse checks.
Technical references
Core Flux, Gap & Loss
Open calculator ↗Flux
Bmax = L·Ipk/(N·Ae) | ΔB = L·ΔIpp/(N·Ae)
Compare the absolute endpoint flux with the saturation threshold. A bipolar peak-to-peak swing can exceed that threshold while both endpoints stay within it. Hdc = N·Idc/ℓe uses the midpoint of the entered triangular current. Use it with the actual powder-core DC-bias curve and enter inductance at the operating bias.
Gap
ℓg = μ₀·N²·Ae/L − ℓe/μr
If the computed gap is negative, the ungapped core cannot reach the target L at this turn count. The estimate neglects fringing and uses linear permeability. For a powder core the result is an equivalent reluctance, not a machining dimension.
Core loss
Pcore = Ve · k · fs^α · (ΔB/2)^β
Enter frequency in Hz and flux in tesla when fitting custom coefficients for a loss density in W/m³. Ferrite coefficients are approximate fits to typical hot datasheet points. Powder presets use published coefficients for representative 60-permeability toroids. Use your exact material, geometry, temperature and waveform for final loss estimates.