ASME VIII-1 / UG-99 & UG-100
Proof test with equal allowable stresses
Both allowable stresses are 20 ksi for a 150 psig vessel. The test gauge elevation difference is zero.
Inputs
Reset restores this worked example. View results ↑
Screening result
Edit inputs ↓ LivePneumatic testing has severe stored-energy hazards. Use an approved test plan and independent pressure-safety review.
Calculation breakdown
- Controlling stress ratio Sₜ/Sd
- 1
- Hydrostatic multiplier
- 1.3
- Hydrostatic gauge target
- 195 psig
- Static head below gauge
- 0 psig
- Hydrostatic bottom pressure
- 195 psig
- Pneumatic gauge target
- 165 psig
- Pneumatic absolute pressure
- 179.696 psia
- Water fill weight
- 1,666.08 lb
- Isentropic stored energy
- 1,198.229 kJ
- TNT mass energy equivalence
- 0.6314 lb TNT eq.
- Entered test limit reserve
- 45 psig
Worked calculation
Both allowable stresses are 20 ksi for a 150 psig vessel. The test gauge elevation difference is zero.
- Controlling stress ratio Sₜ/Sd
- 1
- Hydrostatic gauge target
- 195 psig
- Pneumatic gauge target
- 165 psig
A unity ratio leaves the nominal factor as the only pressure multiplier. The hydrostatic bottom and gauge pressures match for this elevation input.
Calculation basis
Required stress ratio
Enter the test and design allowable stresses from the material giving the lowest ratio. The factors set screening targets at the gauge. Add liquid head when checking the bottom or other lower components.
Ph = fh·MAWP·(Sₜ/Sd) · Pp = 1.10·MAWP·(Sₜ/Sd)Water and stored energy
Compute the full water fill mass at the entered density. Gas energy assumes isentropic expansion of the total test volume to local atmosphere. Use absolute pressures. The TNT comparison uses the NIST energy convention of 4.184 MJ/kg.
Energy = Pabs·V·[1 − (Patm/Pabs)^((k−1)/k)]/(k−1)Check the entered limit
The bar compares the larger of hydrostatic bottom pressure and uniform pneumatic pressure with the entered component limit. Use approved limits for the actual materials, temperature, equipment and test plan.
Pressure reserve = Plimit − max(Ph,bottom, Pp)
Pneumatic failure can release severe stored energy. Obtain an approved test procedure and pressure-safety review. Hydrostatic weight and actual vessel support, venting, metal temperature, component limits and allowable stress at test conditions require review.