ASME VIII-1 / UG-99 & UG-100
Tall vessel hydrostatic head correction
The water elevation from the test gauge to a lower component is 216 inches in this vertical vessel.
Inputs
Reset restores this worked example. View results ↑
Screening result
Edit inputs ↓ LivePneumatic testing has severe stored-energy hazards. Use an approved test plan and independent pressure-safety review.
Calculation breakdown
- Controlling stress ratio Sₜ/Sd
- 1
- Hydrostatic multiplier
- 1.3
- Hydrostatic gauge target
- 156 psig
- Static head below gauge
- 7.789 psig
- Hydrostatic bottom pressure
- 163.789 psig
- Pneumatic gauge target
- 132 psig
- Pneumatic absolute pressure
- 146.696 psia
- Water fill weight
- 17,493.8 lb
- Isentropic stored energy
- 9,684.216 kJ
- TNT mass energy equivalence
- 5.1028 lb TNT eq.
- Entered test limit reserve
- 11.211 psig
Worked calculation
The water elevation from the test gauge to a lower component is 216 inches in this vertical vessel.
- Static head below gauge
- 7.789 psig
- Hydrostatic bottom pressure
- 163.789 psig
- Water fill weight
- 17,493.8 lb
Even at modest gauge pressure, the fluid column contributes local hydrostatic pressure and substantial support load.
Calculation basis
Required stress ratio
Enter the test and design allowable stresses from the material giving the lowest ratio. The factors set screening targets at the gauge. Add liquid head when checking the bottom or other lower components.
Ph = fh·MAWP·(Sₜ/Sd) · Pp = 1.10·MAWP·(Sₜ/Sd)Water and stored energy
Compute the full water fill mass at the entered density. Gas energy assumes isentropic expansion of the total test volume to local atmosphere. Use absolute pressures. The TNT comparison uses the NIST energy convention of 4.184 MJ/kg.
Energy = Pabs·V·[1 − (Patm/Pabs)^((k−1)/k)]/(k−1)Check the entered limit
The bar compares the larger of hydrostatic bottom pressure and uniform pneumatic pressure with the entered component limit. Use approved limits for the actual materials, temperature, equipment and test plan.
Pressure reserve = Plimit − max(Ph,bottom, Pp)
Pneumatic failure can release severe stored energy. Obtain an approved test procedure and pressure-safety review. Hydrostatic weight and actual vessel support, venting, metal temperature, component limits and allowable stress at test conditions require review.