ASME VIII-1 / UG-99 & UG-100
Legacy 1.5× hydrostatic comparison
The test basis uses the historical 1.50 multiplier for comparison against a reviewed 265 psig limit.
Inputs
Reset restores this worked example. View results ↑
Screening result
Edit inputs ↓ LiveLegacy 1.5× is an explicit historical comparison. Pneumatic testing has severe stored-energy hazards. Use an approved test plan.
Calculation breakdown
- Controlling stress ratio Sₜ/Sd
- 1
- Hydrostatic multiplier
- 1.5
- Hydrostatic gauge target
- 262.5 psig
- Static head below gauge
- 2.596 psig
- Hydrostatic bottom pressure
- 265.096 psig
- Pneumatic gauge target
- 192.5 psig
- Pneumatic absolute pressure
- 207.196 psia
- Water fill weight
- 2,499.11 lb
- Isentropic stored energy
- 2,151.478 kJ
- TNT mass energy equivalence
- 1.1337 lb TNT eq.
- Entered test limit reserve
- -0.096 psig
Worked calculation
The test basis uses the historical 1.50 multiplier for comparison against a reviewed 265 psig limit.
- Hydrostatic gauge target
- 262.5 psig
- Hydrostatic bottom pressure
- 265.096 psig
- Entered test limit reserve
- -0.096 psig
The historical factor changes the hydrostatic target. The added head can push the bottom pressure above the entered component limit.
Calculation basis
Required stress ratio
Enter the test and design allowable stresses from the material giving the lowest ratio. The factors set screening targets at the gauge. Add liquid head when checking the bottom or other lower components.
Ph = fh·MAWP·(Sₜ/Sd) · Pp = 1.10·MAWP·(Sₜ/Sd)Water and stored energy
Compute the full water fill mass at the entered density. Gas energy assumes isentropic expansion of the total test volume to local atmosphere. Use absolute pressures. The TNT comparison uses the NIST energy convention of 4.184 MJ/kg.
Energy = Pabs·V·[1 − (Patm/Pabs)^((k−1)/k)]/(k−1)Check the entered limit
The bar compares the larger of hydrostatic bottom pressure and uniform pneumatic pressure with the entered component limit. Use approved limits for the actual materials, temperature, equipment and test plan.
Pressure reserve = Plimit − max(Ph,bottom, Pp)
Pneumatic failure can release severe stored energy. Obtain an approved test procedure and pressure-safety review. Hydrostatic weight and actual vessel support, venting, metal temperature, component limits and allowable stress at test conditions require review.