ASME VIII-1 / UG-99 & UG-100

Pneumatic energy at reduced atmospheric pressure

A 300-gallon vessel uses an 11.3 psia local atmosphere in the gas expansion estimate.

Inputs

Pressure basis
psig
ksi
ksi
psig
Test media
US gal
in
lb/gal
psia

Reset restores this worked example. View results ↑

Screening result

Edit inputs ↓ Live
HYDRO TEST 273.333 psig PNEUMATIC TEST 231.282 psig WATER FILL 2499.11 lb GAS ENERGY 2771.285 kJ TEST MEDIA SECTIONS Water filledCompressed gas Entered test limit headroom PASS SCREEN 0% 100% LIMIT 150%+
275.064 psig demand / 330 psig limit

Pneumatic testing has severe stored-energy hazards. Use an approved test plan and independent pressure-safety review.

Export or share
Calculation breakdown
Controlling stress ratio Sₜ/Sd
1.0513
Hydrostatic multiplier
1.3
Hydrostatic gauge target
273.333 psig
Static head below gauge
1.731 psig
Hydrostatic bottom pressure
275.064 psig
Pneumatic gauge target
231.282 psig
Pneumatic absolute pressure
242.582 psia
Water fill weight
2,499.11 lb
Isentropic stored energy
2,771.285 kJ
TNT mass energy equivalence
1.4602 lb TNT eq.
Entered test limit reserve
54.936 psig
ORIGINAL PRESET

Worked calculation

A 300-gallon vessel uses an 11.3 psia local atmosphere in the gas expansion estimate.

Pneumatic absolute pressure
242.582 psia
Isentropic stored energy
2,771.285 kJ
TNT mass energy equivalence
1.4602 lb TNT eq.

Gauge target comes from MAWP and the stress ratio. Local absolute atmosphere enters both the pressurized and final states of the gas energy calculation.

Calculation basis

  1. Required stress ratio

    Enter the test and design allowable stresses from the material giving the lowest ratio. The factors set screening targets at the gauge. Add liquid head when checking the bottom or other lower components.

    Ph = fh·MAWP·(Sₜ/Sd) · Pp = 1.10·MAWP·(Sₜ/Sd)

  2. Water and stored energy

    Compute the full water fill mass at the entered density. Gas energy assumes isentropic expansion of the total test volume to local atmosphere. Use absolute pressures. The TNT comparison uses the NIST energy convention of 4.184 MJ/kg.

    Energy = Pabs·V·[1 − (Patm/Pabs)^((k−1)/k)]/(k−1)

  3. Check the entered limit

    The bar compares the larger of hydrostatic bottom pressure and uniform pneumatic pressure with the entered component limit. Use approved limits for the actual materials, temperature, equipment and test plan.

    Pressure reserve = Plimit − max(Ph,bottom, Pp)

Pneumatic failure can release severe stored energy. Obtain an approved test procedure and pressure-safety review. Hydrostatic weight and actual vessel support, venting, metal temperature, component limits and allowable stress at test conditions require review.

Sources and verification scope ↗