ASME VIII-1 / UG-99 & UG-100

Proof test with equal allowable stresses

Both allowable stresses are 20 ksi for a 150 psig vessel. The test gauge elevation difference is zero.

Inputs

Pressure basis
psig
ksi
ksi
psig
Test media
US gal
in
lb/gal
psia

Reset restores this worked example. View results ↑

Screening result

Edit inputs ↓ Live
HYDRO TEST 195 psig PNEUMATIC TEST 165 psig WATER FILL 1666.08 lb GAS ENERGY 1198.229 kJ TEST MEDIA SECTIONS Water filledCompressed gas Entered test limit headroom PASS SCREEN 0% 100% LIMIT 150%+
195 psig demand / 240 psig limit

Pneumatic testing has severe stored-energy hazards. Use an approved test plan and independent pressure-safety review.

Export or share
Calculation breakdown
Controlling stress ratio Sₜ/Sd
1
Hydrostatic multiplier
1.3
Hydrostatic gauge target
195 psig
Static head below gauge
0 psig
Hydrostatic bottom pressure
195 psig
Pneumatic gauge target
165 psig
Pneumatic absolute pressure
179.696 psia
Water fill weight
1,666.08 lb
Isentropic stored energy
1,198.229 kJ
TNT mass energy equivalence
0.6314 lb TNT eq.
Entered test limit reserve
45 psig
ORIGINAL PRESET

Worked calculation

Both allowable stresses are 20 ksi for a 150 psig vessel. The test gauge elevation difference is zero.

Controlling stress ratio Sₜ/Sd
1
Hydrostatic gauge target
195 psig
Pneumatic gauge target
165 psig

A unity ratio leaves the nominal factor as the only pressure multiplier. The hydrostatic bottom and gauge pressures match for this elevation input.

Calculation basis

  1. Required stress ratio

    Enter the test and design allowable stresses from the material giving the lowest ratio. The factors set screening targets at the gauge. Add liquid head when checking the bottom or other lower components.

    Ph = fh·MAWP·(Sₜ/Sd) · Pp = 1.10·MAWP·(Sₜ/Sd)

  2. Water and stored energy

    Compute the full water fill mass at the entered density. Gas energy assumes isentropic expansion of the total test volume to local atmosphere. Use absolute pressures. The TNT comparison uses the NIST energy convention of 4.184 MJ/kg.

    Energy = Pabs·V·[1 − (Patm/Pabs)^((k−1)/k)]/(k−1)

  3. Check the entered limit

    The bar compares the larger of hydrostatic bottom pressure and uniform pneumatic pressure with the entered component limit. Use approved limits for the actual materials, temperature, equipment and test plan.

    Pressure reserve = Plimit − max(Ph,bottom, Pp)

Pneumatic failure can release severe stored energy. Obtain an approved test procedure and pressure-safety review. Hydrostatic weight and actual vessel support, venting, metal temperature, component limits and allowable stress at test conditions require review.

Sources and verification scope ↗