ASME VIII-1 / UG-99 & UG-100
Pneumatic energy at reduced atmospheric pressure
A 300-gallon vessel uses an 11.3 psia local atmosphere in the gas expansion estimate.
Inputs
Reset restores this worked example. View results ↑
Screening result
Edit inputs ↓ LivePneumatic testing has severe stored-energy hazards. Use an approved test plan and independent pressure-safety review.
Calculation breakdown
- Controlling stress ratio Sₜ/Sd
- 1.0513
- Hydrostatic multiplier
- 1.3
- Hydrostatic gauge target
- 273.333 psig
- Static head below gauge
- 1.731 psig
- Hydrostatic bottom pressure
- 275.064 psig
- Pneumatic gauge target
- 231.282 psig
- Pneumatic absolute pressure
- 242.582 psia
- Water fill weight
- 2,499.11 lb
- Isentropic stored energy
- 2,771.285 kJ
- TNT mass energy equivalence
- 1.4602 lb TNT eq.
- Entered test limit reserve
- 54.936 psig
Worked calculation
A 300-gallon vessel uses an 11.3 psia local atmosphere in the gas expansion estimate.
- Pneumatic absolute pressure
- 242.582 psia
- Isentropic stored energy
- 2,771.285 kJ
- TNT mass energy equivalence
- 1.4602 lb TNT eq.
Gauge target comes from MAWP and the stress ratio. Local absolute atmosphere enters both the pressurized and final states of the gas energy calculation.
Calculation basis
Required stress ratio
Enter the test and design allowable stresses from the material giving the lowest ratio. The factors set screening targets at the gauge. Add liquid head when checking the bottom or other lower components.
Ph = fh·MAWP·(Sₜ/Sd) · Pp = 1.10·MAWP·(Sₜ/Sd)Water and stored energy
Compute the full water fill mass at the entered density. Gas energy assumes isentropic expansion of the total test volume to local atmosphere. Use absolute pressures. The TNT comparison uses the NIST energy convention of 4.184 MJ/kg.
Energy = Pabs·V·[1 − (Patm/Pabs)^((k−1)/k)]/(k−1)Check the entered limit
The bar compares the larger of hydrostatic bottom pressure and uniform pneumatic pressure with the entered component limit. Use approved limits for the actual materials, temperature, equipment and test plan.
Pressure reserve = Plimit − max(Ph,bottom, Pp)
Pneumatic failure can release severe stored energy. Obtain an approved test procedure and pressure-safety review. Hydrostatic weight and actual vessel support, venting, metal temperature, component limits and allowable stress at test conditions require review.