ASME VIII-1 / UG-99 & UG-100

Tall vessel hydrostatic head correction

The water elevation from the test gauge to a lower component is 216 inches in this vertical vessel.

Inputs

Pressure basis
psig
ksi
ksi
psig
Test media
US gal
in
lb/gal
psia

Reset restores this worked example. View results ↑

Screening result

Edit inputs ↓ Live
HYDRO TEST 156 psig PNEUMATIC TEST 132 psig WATER FILL 17493.8 lb GAS ENERGY 9684.216 kJ TEST MEDIA SECTIONS Water filledCompressed gas Entered test limit headroom PASS SCREEN 0% 100% LIMIT 150%+
163.789 psig demand / 175 psig limit

Pneumatic testing has severe stored-energy hazards. Use an approved test plan and independent pressure-safety review.

Export or share
Calculation breakdown
Controlling stress ratio Sₜ/Sd
1
Hydrostatic multiplier
1.3
Hydrostatic gauge target
156 psig
Static head below gauge
7.789 psig
Hydrostatic bottom pressure
163.789 psig
Pneumatic gauge target
132 psig
Pneumatic absolute pressure
146.696 psia
Water fill weight
17,493.8 lb
Isentropic stored energy
9,684.216 kJ
TNT mass energy equivalence
5.1028 lb TNT eq.
Entered test limit reserve
11.211 psig
ORIGINAL PRESET

Worked calculation

The water elevation from the test gauge to a lower component is 216 inches in this vertical vessel.

Static head below gauge
7.789 psig
Hydrostatic bottom pressure
163.789 psig
Water fill weight
17,493.8 lb

Even at modest gauge pressure, the fluid column contributes local hydrostatic pressure and substantial support load.

Calculation basis

  1. Required stress ratio

    Enter the test and design allowable stresses from the material giving the lowest ratio. The factors set screening targets at the gauge. Add liquid head when checking the bottom or other lower components.

    Ph = fh·MAWP·(Sₜ/Sd) · Pp = 1.10·MAWP·(Sₜ/Sd)

  2. Water and stored energy

    Compute the full water fill mass at the entered density. Gas energy assumes isentropic expansion of the total test volume to local atmosphere. Use absolute pressures. The TNT comparison uses the NIST energy convention of 4.184 MJ/kg.

    Energy = Pabs·V·[1 − (Patm/Pabs)^((k−1)/k)]/(k−1)

  3. Check the entered limit

    The bar compares the larger of hydrostatic bottom pressure and uniform pneumatic pressure with the entered component limit. Use approved limits for the actual materials, temperature, equipment and test plan.

    Pressure reserve = Plimit − max(Ph,bottom, Pp)

Pneumatic failure can release severe stored energy. Obtain an approved test procedure and pressure-safety review. Hydrostatic weight and actual vessel support, venting, metal temperature, component limits and allowable stress at test conditions require review.

Sources and verification scope ↗