ASME VIII-1 / UG-37 & UG-40

Nozzle opening reinforcement area calculator

Balance opening area against net shell, neck, weld and pad credit for an isolated radial set-in nozzle.

Inputs

Opening and net walls
in
in
in
in
in
Projections, pad and welds
in
in
in
in
in
in
in

Results update as inputs change. View results ↑

Screening result

Edit inputs ↓ Live
REQUIRED AREA 2.1 in² AREA CREDIT 2.284 in² PAD CREDIT 0.985 in² AREA BALANCE 0.184 in² SET-IN NOZZLE dA₁ shellA₂/A₃ neckA₄ filletA₅ padZone OD 12 in Reinforcement area headroom PASS SCREEN 0% 100% LIMIT 150%+
2.1 in² demand / 2.2843 in² limit

Area replacement covers one radial opening and one plane. Check all required planes, neck minimums, load paths and weld strength.

Export or share
Calculation breakdown
Base removed area d·tᵣ·F
2.1 in²
Required area with strength correction
2.1 in²
A₁ shell excess
0.9 in²
A₂ outward nozzle excess
0.19 in²
A₃ inward nozzle projection
0.14 in²
A₄ fillet welds
0.0693 in²
A₅ pad metal
0.985 in²
Total credited area
2.2843 in²
Net area balance
0.1843 in²
Independent wall check
Shell and neck meet inputs
Nozzle outside diameter
6.56 in
Creditable pad diameter limit
12 in
Candidate OD at entered pad wall
10.1824 in
Candidate wall at entered pad OD
0.2298 in
Credited pad wall
0.25 in
Pad sizing screen
Candidate within zone

Calculation basis

  1. Required area

    Increase the removed pressure-wall area when the nozzle material is weaker than the shell. Use F = 1.00 for padded and non-integrally reinforced openings. Enter a lower F only for a verified integrally reinforced opening and plane. Use dimensions after corrosion.

    A = d·tᵣ·F + 2tₙ·tᵣ·F(1 − fᵣ)

  2. Eligible credit

    Keep neck and equal-leg fillet credit within the radial and normal limits. The outward fillet uses the weaker of neck and pad when it joins a pad. The inward projection assumes the entered net neck wall also applies inside.

    Aavailable = A₁ + A₂ + A₃ + A₄ + A₅

  3. Pad sizing

    Credit pad width between nozzle OD and the radial boundary. Candidate pad sizes use pad-free outward neck height and omit outer fillet credit to keep the geometry change conservative. A dash indicates that a candidate is inapplicable or exceeds the modeled zone.

    A₅ = (ODcredited − ODneck)·tpad·fpad

Screen one isolated radial set-in opening in a pressurized cylindrical wall. Verify UG-36 limits, the governing reinforcement planes, weld load paths, UG-45 neck thickness, nearby openings, external loads and attachment details.

Sources and verification scope ↗