ASME VIII-1 / UG-37 & UG-40

Oversize pad limited by the UG-40 zone

A 16-inch pad surrounds a 5-inch opening. Some of the installed pad lies beyond the radial boundary.

Inputs

Opening and net walls
in
in
in
in
in
Projections, pad and welds
in
in
in
in
in
in
in

Reset restores this worked example. View results ↑

Screening result

Edit inputs ↓ Live
REQUIRED AREA 1.85 in² AREA CREDIT 2.462 in² PAD CREDIT 1.421 in² AREA BALANCE 0.612 in² SET-IN NOZZLE dA₁ shellA₂/A₃ neckA₄ filletA₅ padZone OD 10 in Reinforcement area headroom PASS SCREEN 0% 100% LIMIT 150%+
1.85 in² demand / 2.4616 in² limit

Area replacement covers one radial opening and one plane. Check all required planes, neck minimums, load paths and weld strength.

Export or share
Calculation breakdown
Base removed area d·tᵣ·F
1.85 in²
Required area with strength correction
1.85 in²
A₁ shell excess
0.65 in²
A₂ outward nozzle excess
0.204 in²
A₃ inward nozzle projection
0.14 in²
A₄ fillet welds
0.0468 in²
A₅ pad metal
1.4208 in²
Total credited area
2.4616 in²
Net area balance
0.6116 in²
Independent wall check
Shell and neck meet inputs
Nozzle outside diameter
5.56 in
Creditable pad diameter limit
10 in
Candidate OD at entered pad wall
8.39 in
Candidate wall at entered pad OD
0.204 in
Credited pad wall
0.32 in
Pad sizing screen
Candidate within zone
ORIGINAL PRESET

Worked calculation

A 16-inch pad surrounds a 5-inch opening. Some of the installed pad lies beyond the radial boundary.

A₅ pad metal
1.4208 in²
Net area balance
0.6116 in²
Creditable pad diameter limit
10 in

The model caps credited pad width. Enlarging pad OD past the limit leaves the credited metal area fixed.

Calculation basis

  1. Required area

    Increase the removed pressure-wall area when the nozzle material is weaker than the shell. Use F = 1.00 for padded and non-integrally reinforced openings. Enter a lower F only for a verified integrally reinforced opening and plane. Use dimensions after corrosion.

    A = d·tᵣ·F + 2tₙ·tᵣ·F(1 − fᵣ)

  2. Eligible credit

    Keep neck and equal-leg fillet credit within the radial and normal limits. The outward fillet uses the weaker of neck and pad when it joins a pad. The inward projection assumes the entered net neck wall also applies inside.

    Aavailable = A₁ + A₂ + A₃ + A₄ + A₅

  3. Pad sizing

    Credit pad width between nozzle OD and the radial boundary. Candidate pad sizes use pad-free outward neck height and omit outer fillet credit to keep the geometry change conservative. A dash indicates that a candidate is inapplicable or exceeds the modeled zone.

    A₅ = (ODcredited − ODneck)·tpad·fpad

Screen one isolated radial set-in opening in a pressurized cylindrical wall. Verify UG-36 limits, the governing reinforcement planes, weld load paths, UG-45 neck thickness, nearby openings, external loads and attachment details.

Sources and verification scope ↗