ASME VIII-1 / UG-37 & UG-40

Weaker nozzle material in an 8-inch opening

The neck allowable is 72% of the shell allowable and the pad allowable is 90% of shell.

Inputs

Opening and net walls
in
in
in
in
in
Projections, pad and welds
in
in
in
in
in
in
in

Reset restores this worked example. View results ↑

Screening result

Edit inputs ↓ Live
REQUIRED AREA 3.438 in² AREA CREDIT 2.476 in² PAD CREDIT 0.977 in² AREA BALANCE -0.962 in² SET-IN NOZZLE dA₁ shellA₂/A₃ neckA₄ filletA₅ padZone OD 16 in Reinforcement area headroom FAIL SCREEN 0% 100% LIMIT 150%+
3.4376 in² demand / 2.4756 in² limit

Area replacement covers one radial opening and one plane. Check all required planes, neck minimums, load paths and weld strength.

Export or share
Calculation breakdown
Base removed area d·tᵣ·F
3.36 in²
Required area with strength correction
3.4376 in²
A₁ shell excess
1.0941 in²
A₂ outward nozzle excess
0.2322 in²
A₃ inward nozzle projection
0.1188 in²
A₄ fillet welds
0.0539 in²
A₅ pad metal
0.9765 in²
Total credited area
2.4756 in²
Net area balance
-0.962 in²
Independent wall check
Shell and neck meet inputs
Nozzle outside diameter
8.66 in
Creditable pad diameter limit
16 in
Candidate OD at entered pad wall
—
Candidate wall at entered pad OD
0.5213 in
Credited pad wall
0.25 in
Pad sizing screen
Candidate within zone
ORIGINAL PRESET

Worked calculation

The neck allowable is 72% of the shell allowable and the pad allowable is 90% of shell.

Base removed area d·tᵣ·F
3.36 in²
Required area with strength correction
3.4376 in²
Net area balance
-0.962 in²

The weaker neck both increases required area and reduces eligible neck and weld credit. Review the calculated shortfall before changing pad dimensions.

Calculation basis

  1. Required area

    Increase the removed pressure-wall area when the nozzle material is weaker than the shell. Use F = 1.00 for padded and non-integrally reinforced openings. Enter a lower F only for a verified integrally reinforced opening and plane. Use dimensions after corrosion.

    A = d·tᵣ·F + 2tₙ·tᵣ·F(1 − fᵣ)

  2. Eligible credit

    Keep neck and equal-leg fillet credit within the radial and normal limits. The outward fillet uses the weaker of neck and pad when it joins a pad. The inward projection assumes the entered net neck wall also applies inside.

    Aavailable = A₁ + A₂ + A₃ + A₄ + A₅

  3. Pad sizing

    Credit pad width between nozzle OD and the radial boundary. Candidate pad sizes use pad-free outward neck height and omit outer fillet credit to keep the geometry change conservative. A dash indicates that a candidate is inapplicable or exceeds the modeled zone.

    A₅ = (ODcredited − ODneck)·tpad·fpad

Screen one isolated radial set-in opening in a pressurized cylindrical wall. Verify UG-36 limits, the governing reinforcement planes, weld load paths, UG-45 neck thickness, nearby openings, external loads and attachment details.

Sources and verification scope ↗