ASME VIII-1 / UG-37 & UG-40

Padded opening with deficient nozzle wall

An opening has generous pad stock, but the net neck thickness is below its input required wall.

Inputs

Opening and net walls
in
in
in
in
in
Projections, pad and welds
in
in
in
in
in
in
in

Reset restores this worked example. View results ↑

Screening result

Edit inputs ↓ Live
REQUIRED AREA 2.1 in² AREA CREDIT 3.399 in² PAD CREDIT 2.36 in² AREA BALANCE 1.299 in² SET-IN NOZZLE dA₁ shellA₂/A₃ neckA₄ filletA₅ padZone OD 12 in Reinforcement area headroom FAIL SCREEN 0% 100% LIMIT 150%+
2.1 in² demand / 3.3993 in² limit

The entered net shell or nozzle wall is below its own required thickness. Pad credit cannot clear that deficiency.

Export or share
Calculation breakdown
Base removed area d·tᵣ·F
2.1 in²
Required area with strength correction
2.1 in²
A₁ shell excess
0.9 in²
A₂ outward nozzle excess
0 in²
A₃ inward nozzle projection
0.07 in²
A₄ fillet welds
0.0693 in²
A₅ pad metal
2.36 in²
Total credited area
3.3993 in²
Net area balance
1.2993 in²
Independent wall check
Shell or neck wall is deficient
Nozzle outside diameter
6.28 in
Creditable pad diameter limit
12 in
Candidate OD at entered pad wall
8.5112 in
Candidate wall at entered pad OD
0.2364 in
Credited pad wall
0.5 in
Pad sizing screen
Candidate within zone
ORIGINAL PRESET

Worked calculation

An opening has generous pad stock, but the net neck thickness is below its input required wall.

A₂ outward nozzle excess
0 in²
Net area balance
1.2993 in²
Independent wall check
Shell or neck wall is deficient

Pad credit can create a positive area balance while the independent neck wall check is still deficient. The overall screening verdict reflects both checks.

Calculation basis

  1. Required area

    Increase the removed pressure-wall area when the nozzle material is weaker than the shell. Use F = 1.00 for padded and non-integrally reinforced openings. Enter a lower F only for a verified integrally reinforced opening and plane. Use dimensions after corrosion.

    A = d·tᵣ·F + 2tₙ·tᵣ·F(1 − fᵣ)

  2. Eligible credit

    Keep neck and equal-leg fillet credit within the radial and normal limits. The outward fillet uses the weaker of neck and pad when it joins a pad. The inward projection assumes the entered net neck wall also applies inside.

    Aavailable = A₁ + A₂ + A₃ + A₄ + A₅

  3. Pad sizing

    Credit pad width between nozzle OD and the radial boundary. Candidate pad sizes use pad-free outward neck height and omit outer fillet credit to keep the geometry change conservative. A dash indicates that a candidate is inapplicable or exceeds the modeled zone.

    A₅ = (ODcredited − ODneck)·tpad·fpad

Screen one isolated radial set-in opening in a pressurized cylindrical wall. Verify UG-36 limits, the governing reinforcement planes, weld load paths, UG-45 neck thickness, nearby openings, external loads and attachment details.

Sources and verification scope ↗