ASME VIII-1 / UG-37 & UG-40
Padded opening with deficient nozzle wall
An opening has generous pad stock, but the net neck thickness is below its input required wall.
Inputs
Reset restores this worked example. View results ↑
Screening result
Edit inputs ↓ LiveThe entered net shell or nozzle wall is below its own required thickness. Pad credit cannot clear that deficiency.
Calculation breakdown
- Base removed area d·tᵣ·F
- 2.1 in²
- Required area with strength correction
- 2.1 in²
- A₁ shell excess
- 0.9 in²
- A₂ outward nozzle excess
- 0 in²
- A₃ inward nozzle projection
- 0.07 in²
- A₄ fillet welds
- 0.0693 in²
- A₅ pad metal
- 2.36 in²
- Total credited area
- 3.3993 in²
- Net area balance
- 1.2993 in²
- Independent wall check
- Shell or neck wall is deficient
- Nozzle outside diameter
- 6.28 in
- Creditable pad diameter limit
- 12 in
- Candidate OD at entered pad wall
- 8.5112 in
- Candidate wall at entered pad OD
- 0.2364 in
- Credited pad wall
- 0.5 in
- Pad sizing screen
- Candidate within zone
Worked calculation
An opening has generous pad stock, but the net neck thickness is below its input required wall.
- A₂ outward nozzle excess
- 0 in²
- Net area balance
- 1.2993 in²
- Independent wall check
- Shell or neck wall is deficient
Pad credit can create a positive area balance while the independent neck wall check is still deficient. The overall screening verdict reflects both checks.
Calculation basis
Required area
Increase the removed pressure-wall area when the nozzle material is weaker than the shell. Use F = 1.00 for padded and non-integrally reinforced openings. Enter a lower F only for a verified integrally reinforced opening and plane. Use dimensions after corrosion.
A = d·tᵣ·F + 2tₙ·tᵣ·F(1 − fᵣ)Eligible credit
Keep neck and equal-leg fillet credit within the radial and normal limits. The outward fillet uses the weaker of neck and pad when it joins a pad. The inward projection assumes the entered net neck wall also applies inside.
Aavailable = A₁ + A₂ + A₃ + A₄ + A₅Pad sizing
Credit pad width between nozzle OD and the radial boundary. Candidate pad sizes use pad-free outward neck height and omit outer fillet credit to keep the geometry change conservative. A dash indicates that a candidate is inapplicable or exceeds the modeled zone.
A₅ = (ODcredited − ODneck)·tpad·fpad
Screen one isolated radial set-in opening in a pressurized cylindrical wall. Verify UG-36 limits, the governing reinforcement planes, weld load paths, UG-45 neck thickness, nearby openings, external loads and attachment details.