ASME VIII-1 / UG-27
48-inch shell at 250 psig
A 48-inch-ID cylindrical vessel has 5/8-inch ordered plate, a 1/8-inch inside corrosion allowance and an 85% longitudinal seam.
Inputs
Reset restores this worked example. View results ↑
Screening result
Edit inputs ↓ LiveShell-only pressure capacity. Check every pressure-boundary component, static head and nonpressure loads for vessel MAWP.
Calculation breakdown
- Circumferential pressure wall
- 0.3579 in
- Longitudinal pressure wall
- 0.1504 in
- Governing pressure wall
- 0.3579 in
- Minimum nominal order wall
- 0.4953 in
- Minimum new wall
- 0.6094 in
- Net corroded wall
- 0.4844 in
- Corroded inside radius
- 24.125 in
- Circumferential MAWP
- 337.258 psig
- Longitudinal MAWP
- 809.611 psig
- Corroded MAWP
- 337.258 psig
- New-and-cold MAWP
- 446.422 psig
- Corroded pressure reserve
- 87.258 psig
- Governing stress
- Circumferential stress
Worked calculation
A 48-inch-ID cylindrical vessel has 5/8-inch ordered plate, a 1/8-inch inside corrosion allowance and an 85% longitudinal seam.
- Circumferential pressure wall
- 0.3579 in
- Corroded MAWP
- 337.258 psig
- New-and-cold MAWP
- 446.422 psig
Compare the circumferential and longitudinal pressure walls. The circumferential wall sets the order thickness. Corrosion and the change in allowable stress reduce the corroded MAWP.
Calculation basis
Corroded dimensions
The entered radius is as new. Add inside corrosion allowance to that radius. Reduce nominal thickness by mill undertolerance and then subtract corrosion allowance.
R = Rnew + CA · tnet = tnom(1 − u) − CARequired pressure wall
Use the longitudinal weld efficiency for hoop stress and the girth weld efficiency for longitudinal stress. The larger pressure wall controls the nominal order thickness.
th = PR/(SEh − 0.6P) · tl = PR/(2SEl + 0.4P)Reverse the equations for MAWP
Use hot allowable stress and net geometry for corroded MAWP. The cold case uses the minimum new wall, new radius and cold allowable stress. Each result is the lower of the two stress checks.
Ph = SEh t/(R + 0.6t) · Pl = 2SEl t/(R − 0.4t)
Use local gauge design pressure, including static head where applicable. This screen covers pressure-only wall in the stated UG-27 range. Confirm UG-16 minimums, allowable stresses, weld examination, external loads, and each pressure-boundary part.