ASME VIII-1 / UG-27
Zero-corrosion cold and hot comparison
The example uses the same allowable stress at both temperatures and zero corrosion allowance for comparison.
Inputs
Reset restores this worked example. View results ↑
Screening result
Edit inputs ↓ LiveShell-only pressure capacity. Check every pressure-boundary component, static head and nonpressure loads for vessel MAWP.
Calculation breakdown
- Circumferential pressure wall
- 0.22 in
- Longitudinal pressure wall
- 0.0929 in
- Governing pressure wall
- 0.22 in
- Minimum nominal order wall
- 0.2257 in
- Minimum new wall
- 0.3656 in
- Net corroded wall
- 0.3656 in
- Corroded inside radius
- 24 in
- Circumferential MAWP
- 256.639 psig
- Longitudinal MAWP
- 613.111 psig
- Corroded MAWP
- 256.639 psig
- New-and-cold MAWP
- 256.639 psig
- Corroded pressure reserve
- 101.639 psig
- Governing stress
- Circumferential stress
Worked calculation
The example uses the same allowable stress at both temperatures and zero corrosion allowance for comparison.
- Net corroded wall
- 0.3656 in
- Corroded MAWP
- 256.639 psig
- New-and-cold MAWP
- 256.639 psig
New and corroded pressure capacities coincide because the temperature allowable, wall and inside radius are the same.
Calculation basis
Corroded dimensions
The entered radius is as new. Add inside corrosion allowance to that radius. Reduce nominal thickness by mill undertolerance and then subtract corrosion allowance.
R = Rnew + CA · tnet = tnom(1 − u) − CARequired pressure wall
Use the longitudinal weld efficiency for hoop stress and the girth weld efficiency for longitudinal stress. The larger pressure wall controls the nominal order thickness.
th = PR/(SEh − 0.6P) · tl = PR/(2SEl + 0.4P)Reverse the equations for MAWP
Use hot allowable stress and net geometry for corroded MAWP. The cold case uses the minimum new wall, new radius and cold allowable stress. Each result is the lower of the two stress checks.
Ph = SEh t/(R + 0.6t) · Pl = 2SEl t/(R − 0.4t)
Use local gauge design pressure, including static head where applicable. This screen covers pressure-only wall in the stated UG-27 range. Confirm UG-16 minimums, allowable stresses, weld examination, external loads, and each pressure-boundary part.