ASME VIII-1 / UG-27

Tubular shell with 12.5% mill loss

A small tubular shell is entered with a mill undertolerance of 12.5%, based on an assumed product specification for the example.

Inputs

Pressure and dimensions
psig
in
in
in
Material and joints
ksi
ksi
%

Reset restores this worked example. View results ↑

Screening result

Edit inputs ↓ Live
PRESSURE WALL 0.221 in MINIMUM NOM. 0.324 in CORRODED MAWP 1418.44 psig COLD MAWP 1745.843 psig CYLINDRICAL WALL Net wall 0.375 inAxial loadHoop load Corroded pressure headroom PASS SCREEN 0% 100% LIMIT 150%+
850 psig demand / 1,418.44 psig limit

Shell-only pressure capacity. Check every pressure-boundary component, static head and nonpressure loads for vessel MAWP.

Export or share
Calculation breakdown
Circumferential pressure wall
0.2208 in
Longitudinal pressure wall
0.1067 in
Governing pressure wall
0.2208 in
Minimum nominal order wall
0.3238 in
Minimum new wall
0.4375 in
Net corroded wall
0.375 in
Corroded inside radius
5.0625 in
Circumferential MAWP
1,418.44 psig
Longitudinal MAWP
3,053.435 psig
Corroded MAWP
1,418.44 psig
New-and-cold MAWP
1,745.843 psig
Corroded pressure reserve
568.44 psig
Governing stress
Circumferential stress
ORIGINAL PRESET

Worked calculation

A small tubular shell is entered with a mill undertolerance of 12.5%, based on an assumed product specification for the example.

Minimum nominal order wall
0.3238 in
Minimum new wall
0.4375 in
Net corroded wall
0.375 in

Apply the mill loss before subtracting corrosion. The nominal order wall reverses that sequence by adding corrosion before dividing by retained wall fraction.

Calculation basis

  1. Corroded dimensions

    The entered radius is as new. Add inside corrosion allowance to that radius. Reduce nominal thickness by mill undertolerance and then subtract corrosion allowance.

    R = Rnew + CA · tnet = tnom(1 − u) − CA

  2. Required pressure wall

    Use the longitudinal weld efficiency for hoop stress and the girth weld efficiency for longitudinal stress. The larger pressure wall controls the nominal order thickness.

    th = PR/(SEh − 0.6P) · tl = PR/(2SEl + 0.4P)

  3. Reverse the equations for MAWP

    Use hot allowable stress and net geometry for corroded MAWP. The cold case uses the minimum new wall, new radius and cold allowable stress. Each result is the lower of the two stress checks.

    Ph = SEh t/(R + 0.6t) · Pl = 2SEl t/(R − 0.4t)

Use local gauge design pressure, including static head where applicable. This screen covers pressure-only wall in the stated UG-27 range. Confirm UG-16 minimums, allowable stresses, weld examination, external loads, and each pressure-boundary part.

Sources and verification scope ↗