ASME VIII-1 / UG-27
Tubular shell with 12.5% mill loss
A small tubular shell is entered with a mill undertolerance of 12.5%, based on an assumed product specification for the example.
Inputs
Reset restores this worked example. View results ↑
Screening result
Edit inputs ↓ LiveShell-only pressure capacity. Check every pressure-boundary component, static head and nonpressure loads for vessel MAWP.
Calculation breakdown
- Circumferential pressure wall
- 0.2208 in
- Longitudinal pressure wall
- 0.1067 in
- Governing pressure wall
- 0.2208 in
- Minimum nominal order wall
- 0.3238 in
- Minimum new wall
- 0.4375 in
- Net corroded wall
- 0.375 in
- Corroded inside radius
- 5.0625 in
- Circumferential MAWP
- 1,418.44 psig
- Longitudinal MAWP
- 3,053.435 psig
- Corroded MAWP
- 1,418.44 psig
- New-and-cold MAWP
- 1,745.843 psig
- Corroded pressure reserve
- 568.44 psig
- Governing stress
- Circumferential stress
Worked calculation
A small tubular shell is entered with a mill undertolerance of 12.5%, based on an assumed product specification for the example.
- Minimum nominal order wall
- 0.3238 in
- Minimum new wall
- 0.4375 in
- Net corroded wall
- 0.375 in
Apply the mill loss before subtracting corrosion. The nominal order wall reverses that sequence by adding corrosion before dividing by retained wall fraction.
Calculation basis
Corroded dimensions
The entered radius is as new. Add inside corrosion allowance to that radius. Reduce nominal thickness by mill undertolerance and then subtract corrosion allowance.
R = Rnew + CA · tnet = tnom(1 − u) − CARequired pressure wall
Use the longitudinal weld efficiency for hoop stress and the girth weld efficiency for longitudinal stress. The larger pressure wall controls the nominal order thickness.
th = PR/(SEh − 0.6P) · tl = PR/(2SEl + 0.4P)Reverse the equations for MAWP
Use hot allowable stress and net geometry for corroded MAWP. The cold case uses the minimum new wall, new radius and cold allowable stress. Each result is the lower of the two stress checks.
Ph = SEh t/(R + 0.6t) · Pl = 2SEl t/(R − 0.4t)
Use local gauge design pressure, including static head where applicable. This screen covers pressure-only wall in the stated UG-27 range. Confirm UG-16 minimums, allowable stresses, weld examination, external loads, and each pressure-boundary part.