ASME VIII-1 / UG-27
Shell with a 0.70 longitudinal seam
A 36-inch-ID vessel operates at 300 psig with different efficiencies for its longitudinal and girth welds.
Inputs
Reset restores this worked example. View results ↑
Screening result
Edit inputs ↓ LiveShell-only pressure capacity. Check every pressure-boundary component, static head and nonpressure loads for vessel MAWP.
Calculation breakdown
- Circumferential pressure wall
- 0.3921 in
- Longitudinal pressure wall
- 0.1588 in
- Governing pressure wall
- 0.3921 in
- Minimum nominal order wall
- 0.4663 in
- Minimum new wall
- 0.6094 in
- Net corroded wall
- 0.5469 in
- Corroded inside radius
- 18.0625 in
- Circumferential MAWP
- 416.313 psig
- Longitudinal MAWP
- 1,042.032 psig
- Corroded MAWP
- 416.313 psig
- New-and-cold MAWP
- 487.749 psig
- Corroded pressure reserve
- 116.313 psig
- Governing stress
- Circumferential stress
Worked calculation
A 36-inch-ID vessel operates at 300 psig with different efficiencies for its longitudinal and girth welds.
- Circumferential pressure wall
- 0.3921 in
- Longitudinal pressure wall
- 0.1588 in
- Corroded MAWP
- 416.313 psig
The longitudinal seam enters the circumferential stress equation. Change the seam efficiency to see its impact on required thickness and corroded MAWP.
Calculation basis
Corroded dimensions
The entered radius is as new. Add inside corrosion allowance to that radius. Reduce nominal thickness by mill undertolerance and then subtract corrosion allowance.
R = Rnew + CA · tnet = tnom(1 − u) − CARequired pressure wall
Use the longitudinal weld efficiency for hoop stress and the girth weld efficiency for longitudinal stress. The larger pressure wall controls the nominal order thickness.
th = PR/(SEh − 0.6P) · tl = PR/(2SEl + 0.4P)Reverse the equations for MAWP
Use hot allowable stress and net geometry for corroded MAWP. The cold case uses the minimum new wall, new radius and cold allowable stress. Each result is the lower of the two stress checks.
Ph = SEh t/(R + 0.6t) · Pl = 2SEl t/(R − 0.4t)
Use local gauge design pressure, including static head where applicable. This screen covers pressure-only wall in the stated UG-27 range. Confirm UG-16 minimums, allowable stresses, weld examination, external loads, and each pressure-boundary part.