ASME VIII-1 / UG-27

Shell with a 0.70 longitudinal seam

A 36-inch-ID vessel operates at 300 psig with different efficiencies for its longitudinal and girth welds.

Inputs

Pressure and dimensions
psig
in
in
in
Material and joints
ksi
ksi
%

Reset restores this worked example. View results ↑

Screening result

Edit inputs ↓ Live
PRESSURE WALL 0.392 in MINIMUM NOM. 0.466 in CORRODED MAWP 416.313 psig COLD MAWP 487.749 psig CYLINDRICAL WALL Net wall 0.547 inAxial loadHoop load Corroded pressure headroom PASS SCREEN 0% 100% LIMIT 150%+
300 psig demand / 416.313 psig limit

Shell-only pressure capacity. Check every pressure-boundary component, static head and nonpressure loads for vessel MAWP.

Export or share
Calculation breakdown
Circumferential pressure wall
0.3921 in
Longitudinal pressure wall
0.1588 in
Governing pressure wall
0.3921 in
Minimum nominal order wall
0.4663 in
Minimum new wall
0.6094 in
Net corroded wall
0.5469 in
Corroded inside radius
18.0625 in
Circumferential MAWP
416.313 psig
Longitudinal MAWP
1,042.032 psig
Corroded MAWP
416.313 psig
New-and-cold MAWP
487.749 psig
Corroded pressure reserve
116.313 psig
Governing stress
Circumferential stress
ORIGINAL PRESET

Worked calculation

A 36-inch-ID vessel operates at 300 psig with different efficiencies for its longitudinal and girth welds.

Circumferential pressure wall
0.3921 in
Longitudinal pressure wall
0.1588 in
Corroded MAWP
416.313 psig

The longitudinal seam enters the circumferential stress equation. Change the seam efficiency to see its impact on required thickness and corroded MAWP.

Calculation basis

  1. Corroded dimensions

    The entered radius is as new. Add inside corrosion allowance to that radius. Reduce nominal thickness by mill undertolerance and then subtract corrosion allowance.

    R = Rnew + CA · tnet = tnom(1 − u) − CA

  2. Required pressure wall

    Use the longitudinal weld efficiency for hoop stress and the girth weld efficiency for longitudinal stress. The larger pressure wall controls the nominal order thickness.

    th = PR/(SEh − 0.6P) · tl = PR/(2SEl + 0.4P)

  3. Reverse the equations for MAWP

    Use hot allowable stress and net geometry for corroded MAWP. The cold case uses the minimum new wall, new radius and cold allowable stress. Each result is the lower of the two stress checks.

    Ph = SEh t/(R + 0.6t) · Pl = 2SEl t/(R − 0.4t)

Use local gauge design pressure, including static head where applicable. This screen covers pressure-only wall in the stated UG-27 range. Confirm UG-16 minimums, allowable stresses, weld examination, external loads, and each pressure-boundary part.

Sources and verification scope ↗