ASME VIII-1 / UG-27

Zero-corrosion cold and hot comparison

The example uses the same allowable stress at both temperatures and zero corrosion allowance for comparison.

Inputs

Pressure and dimensions
psig
in
in
in
Material and joints
ksi
ksi
%

Reset restores this worked example. View results ↑

Screening result

Edit inputs ↓ Live
PRESSURE WALL 0.22 in MINIMUM NOM. 0.226 in CORRODED MAWP 256.639 psig COLD MAWP 256.639 psig CYLINDRICAL WALL Net wall 0.366 inAxial loadHoop load Corroded pressure headroom PASS SCREEN 0% 100% LIMIT 150%+
155 psig demand / 256.639 psig limit

Shell-only pressure capacity. Check every pressure-boundary component, static head and nonpressure loads for vessel MAWP.

Export or share
Calculation breakdown
Circumferential pressure wall
0.22 in
Longitudinal pressure wall
0.0929 in
Governing pressure wall
0.22 in
Minimum nominal order wall
0.2257 in
Minimum new wall
0.3656 in
Net corroded wall
0.3656 in
Corroded inside radius
24 in
Circumferential MAWP
256.639 psig
Longitudinal MAWP
613.111 psig
Corroded MAWP
256.639 psig
New-and-cold MAWP
256.639 psig
Corroded pressure reserve
101.639 psig
Governing stress
Circumferential stress
ORIGINAL PRESET

Worked calculation

The example uses the same allowable stress at both temperatures and zero corrosion allowance for comparison.

Net corroded wall
0.3656 in
Corroded MAWP
256.639 psig
New-and-cold MAWP
256.639 psig

New and corroded pressure capacities coincide because the temperature allowable, wall and inside radius are the same.

Calculation basis

  1. Corroded dimensions

    The entered radius is as new. Add inside corrosion allowance to that radius. Reduce nominal thickness by mill undertolerance and then subtract corrosion allowance.

    R = Rnew + CA · tnet = tnom(1 − u) − CA

  2. Required pressure wall

    Use the longitudinal weld efficiency for hoop stress and the girth weld efficiency for longitudinal stress. The larger pressure wall controls the nominal order thickness.

    th = PR/(SEh − 0.6P) · tl = PR/(2SEl + 0.4P)

  3. Reverse the equations for MAWP

    Use hot allowable stress and net geometry for corroded MAWP. The cold case uses the minimum new wall, new radius and cold allowable stress. Each result is the lower of the two stress checks.

    Ph = SEh t/(R + 0.6t) · Pl = 2SEl t/(R − 0.4t)

Use local gauge design pressure, including static head where applicable. This screen covers pressure-only wall in the stated UG-27 range. Confirm UG-16 minimums, allowable stresses, weld examination, external loads, and each pressure-boundary part.

Sources and verification scope ↗