ASME B31.1 / B31.3 beam screen
Pipe support span and sag calculator
Calculate pipe, contents and insulation load, then screen maximum support spacing by sag and longitudinal bending stress.
Inputs
Results
Edit inputs- Maximum span
- 15.3ft
- Mid-span sag
- 0.038in
- Line mass
- 17.03lb/ft
- Stress used
- 9.5%
Peak sag governs the calculated span. Full longitudinal stress and support loads need a separate check.
Support spacing and sag
All calculated values
| Screened support span | 15.297 ft |
|---|---|
| Governing criterion | Peak sag |
| Sag-limited span | 15.297 ft |
| Stress-limited span | 38.86 ft |
| Mid-span sag | 0.038 in |
| Peak sag | 0.038 in |
| Peak longitudinal bending stress | 1.144 ksi |
| Bending allowance used | 9.5 % |
| Outside diameter | 4.5 in |
| Inside diameter | 4.026 in |
| Nominal wall thickness | 0.237 in |
| Second moment I | 7.233 in⁴ |
| Section modulus Z | 3.214 in³ |
| Total distributed mass | 17.029 lb/ft |
| Pipe mass per length | 10.802 lb/ft |
| Fluid mass per length | 5.508 lb/ft |
| Insulation mass per length | 0.719 lb/ft |
Model and limits
The steel section uses nominal OD and wall dimensions. The distributed load includes the steel wall, full contents when selected, and the insulated annulus. The choice is between a simply supported span and two equal continuous spans carrying the same uniform load.
Default peak sag allowance is 0.10 in (2.54 mm). The sag peak for two equal spans is at about 42% of span from the outer support. The largest absolute bending moment is at the interior support. Include pressure, localized component loads, thermal loads, corrosion, support stiffness and combined sustained stress in the final B31.1 or B31.3 review.