ACI 318-19 §9.3 / §9.6 / §22.2

High-strength concrete at the β₁ floor

An 8,500 psi mix puts β₁ on its lower plateau in a 14 × 30 in section.

Edit inputs ↓

Inputs

Editable example

Section
Reinforcement & demand
φMn 552.45kip·ft
Block a 2.85in
Axis c 4.38in
Strain εt 15,491με
AnatomyDiagrammatic scale
Parameter-linked flexure drawing. Diagrammatic scale. RC SECTIONSTRAINWHITNEY BLOCKhb 14 ind 27 ina 2.85 in

Screening

Within screening limits
Moment utilization81.5%
Tension controlled18.5% below the threshold
  • Bending strengthMu ≤ φMn
    Within limit
  • Minimum tension steelAs ≥ As,min per §9.6.1.2
    Within limit
  • Tension controlεt ≥ εty + 0.003 per §9.3.3.1
    Within limit

Positive pure bending of a nonprestressed rectangular beam. The calculation excludes combined axial force, shear, anchorage and the minimum-steel exception in §9.6.1.3.

Calculation readout
QuantityValue
Design moment φMn552.45 kip·ft
Stress block depth a2.85 in
Neutral axis depth c4.38 in
Net tensile strain εt15,491 με
Strength factor φ0.9
Whitney factor β₁0.65
Tension-controlled limit5,069 με
Nominal moment Mn613.83 kip·ft
Minimum tension steel As,min1.742 in²
Concrete compression Cc288 kip
Top steel force Cs,net0 kip
Tension steel force Ts288 kip

Original example

Worked solution

Default calculator ↗

Starting inputs

Section width b
14 in
Overall depth h
30 in
Tension steel depth d
27 in
Tension steel As
4.8 in²
Concrete strength f′c
8,500 psi
Factored moment Mu
450 kip·ft

Calculated result

Design moment φMn
552.45 kip·ft
Stress block depth a
2.85 in
Neutral axis depth c
4.38 in
Net tensile strain εt
15,491 με

The stress-block depth a and neutral-axis depth c remain different. Their ratio is the capped Whitney factor.

Preset screening · Tension controlled · Within limits

How the check works

Code basis ↗
  1. β₁ drops linearly from 0.85 at 4,000 psi by 0.05 per additional 1,000 psi, with a 0.65 floor at 8,000 psi. The two strength thresholds display as approximately 27.6 and 55.2 MPa.
  2. Solve force equilibrium using εcu = 0.003, a = β₁c and elastic-perfectly plastic steel. Deduct 0.85f′c from the stress of top steel inside the concrete block. Sum moments of the compression forces about the tension steel.
  3. Use φ = 0.65 below εty and interpolate to 0.90 at εty + 0.003, with εty = fy/Es. Check tension control and As,min = max(3√f′c, 200)bw d / min(fy, 80 ksi).