Positive pure bending of a nonprestressed rectangular beam. The calculation excludes combined axial force, shear, anchorage and the minimum-steel exception in §9.6.1.3.
β₁ drops linearly from 0.85 at 4,000 psi by 0.05 per additional 1,000 psi, with a 0.65 floor at 8,000 psi. The two strength thresholds display as approximately 27.6 and 55.2 MPa.
Solve force equilibrium using εcu = 0.003, a = β₁c and elastic-perfectly plastic steel. Deduct 0.85f′c from the stress of top steel inside the concrete block. Sum moments of the compression forces about the tension steel.
Use φ = 0.65 below εty and interpolate to 0.90 at εty + 0.003, with εty = fy/Es. Check tension control and As,min = max(3√f′c, 200)bw d / min(fy, 80 ksi).
Rectangular section · pure bending · Limit exceeded
Inputs
Section width b
12 in
Overall depth h
24 in
Tension steel depth d
21.5 in
Tension steel As
1.86 in²
Top steel As′
0 in²
Concrete strength f′c
4,000 psi
Steel yield strength fy
60 ksi
Factored moment Mu
260 kip·ft
Calculated values
Design moment φMn
168.51 kip·ft
Stress block depth a
2.74 in
Neutral axis depth c
3.22 in
Net tensile strain εt
17,044 με
Strength factor φ
0.9
Whitney factor β₁
0.85
Tension-controlled limit
5,069 με
Nominal moment Mn
187.23 kip·ft
Minimum tension steel As,min
0.86 in²
Concrete compression Cc
111.6 kip
Top steel force Cs,net
0 kip
Tension steel force Ts
111.6 kip
Screening
Tension controlled · Moment utilization 154.3%
Bending strength · Outside limit
Minimum tension steel · Within limit
Tension control · Within limit
Positive pure bending of a nonprestressed rectangular beam. The calculation excludes combined axial force, shear, anchorage and the minimum-steel exception in §9.6.1.3.