ACI 318-19 §9.3 / §9.6 / §22.2

Ductile beam with excess moment demand

An ordinary tension-controlled beam is checked at 260 kip·ft with a reduced steel area.

Edit inputs ↓

Inputs

Editable example

Section
Reinforcement & demand
φMn 168.51kip·ft
Block a 2.74in
Axis c 3.22in
Strain εt 17,044με
AnatomyDiagrammatic scale
Parameter-linked flexure drawing. Diagrammatic scale. RC SECTIONSTRAINWHITNEY BLOCKhb 12 ind 21.5 ina 2.74 in

Screening

Limit exceeded
Moment utilization154.3%
Tension controlled54.3% over the threshold
  • Bending strengthMu ≤ φMn
    Outside limit
  • Minimum tension steelAs ≥ As,min per §9.6.1.2
    Within limit
  • Tension controlεt ≥ εty + 0.003 per §9.3.3.1
    Within limit

Positive pure bending of a nonprestressed rectangular beam. The calculation excludes combined axial force, shear, anchorage and the minimum-steel exception in §9.6.1.3.

Calculation readout
QuantityValue
Design moment φMn168.51 kip·ft
Stress block depth a2.74 in
Neutral axis depth c3.22 in
Net tensile strain εt17,044 με
Strength factor φ0.9
Whitney factor β₁0.85
Tension-controlled limit5,069 με
Nominal moment Mn187.23 kip·ft
Minimum tension steel As,min0.86 in²
Concrete compression Cc111.6 kip
Top steel force Cs,net0 kip
Tension steel force Ts111.6 kip

Original example

Worked solution

Default calculator ↗

Starting inputs

Tension steel As
1.86 in²
Factored moment Mu
260 kip·ft

Calculated result

Design moment φMn
168.51 kip·ft
Stress block depth a
2.74 in
Neutral axis depth c
3.22 in
Net tensile strain εt
17,044 με

A ductile strain result can coexist with inadequate strength. Compare Mu directly with φMn.

Preset screening · Tension controlled · Limit exceeded

How the check works

Code basis ↗
  1. β₁ drops linearly from 0.85 at 4,000 psi by 0.05 per additional 1,000 psi, with a 0.65 floor at 8,000 psi. The two strength thresholds display as approximately 27.6 and 55.2 MPa.
  2. Solve force equilibrium using εcu = 0.003, a = β₁c and elastic-perfectly plastic steel. Deduct 0.85f′c from the stress of top steel inside the concrete block. Sum moments of the compression forces about the tension steel.
  3. Use φ = 0.65 below εty and interpolate to 0.90 at εty + 0.003, with εty = fy/Es. Check tension control and As,min = max(3√f′c, 200)bw d / min(fy, 80 ksi).