ACI 318-19 §8.7 / §22.6

Flush slab-edge column

A slab terminates along the side parallel to c₁, leaving a three-sided critical shear perimeter.

Edit inputs ↓

Inputs

Editable example

Reaction & slab
Shear reinforcement
Perimeter bo 75in
Baseline φVc 106.73kip
φVn 106.73kip
Size λs 1 
AnatomyDiagrammatic scale
Parameter-linked punching drawing. Diagrammatic scale. EDGE COLUMN PLANCritical linec₁ 16 ind/2 3.75 inbo 75 in

Screening

Within screening limits
Punching utilization80.6%
(a) basic stress19.4% below the threshold
  • Concrete punching strengthVu ≤ φVc at the inner perimeter
    Within limit

Direct shear only. Supply net Vu at the section. Check unbalanced moment, openings, slab edge offsets, the actual perimeter geometry and local slab flexural steel per §8.6.1.2. For studs, provide the shortest enclosing outer perimeter and verify head, rail and cover detailing.

Calculation readout
QuantityValue
Inner critical perimeter bo75 in
Unreinforced strength φVc106.73 kip
Governing design shear φVn106.73 kip
Size effect factor λs1
Inner demand stress vu152.89 psi
Column aspect ratio βc1.38
Position factor αs30
Concrete stress eq. (a)252.98 psi
Concrete stress eq. (b)310.48 psi
Concrete stress eq. (c)316.23 psi

Original example

Worked solution

Default calculator ↗

Starting inputs

Column position
Edge (c₁ parallel)
Column dimension c₁
16 in
Column dimension c₂
22 in
Factored direct shear Vu
86 kip

Calculated result

Inner critical perimeter bo
75 in
Unreinforced strength φVc
106.73 kip
Governing design shear φVn
106.73 kip
Size effect factor λs
1

Only the three sides inside the slab develop perimeter. Use αs = 30 for the edge condition.

Preset screening · (a) basic stress · Within limits

How the check works

Code basis ↗
  1. Measure bo at d/2 with the column faces flush at modeled free edges. Use the lesser of the three stress equations in Table 22.6.5.2, with βc = long side/short side, αs = 40/30/20 and √f′c limited to 100.
  2. For headed studs, use Table 22.6.6.1 for inner concrete stress and add Vs = Av fyt d/s. Use the actual √f′c for the Table 22.6.6.3 inner ceiling and Table 8.7.7.1.2 spacing threshold. Apply the 100 psi root cap to concrete stress, including 2λsλ√f′c at the supplied outer perimeter.
  3. Apply the full entered net shear to both sections as a conservative outer-perimeter screen. Check Av/s ≥ 2√f′c bo/fyt with actual √f′c per §22.6.8.3 and check the first-row, radial and tangential spacing limits.