Positive pure bending of a nonprestressed rectangular beam. The calculation excludes combined axial force, shear, anchorage and the minimum-steel exception in §9.6.1.3.
β₁ drops linearly from 0.85 at 4,000 psi by 0.05 per additional 1,000 psi, with a 0.65 floor at 8,000 psi. The two strength thresholds display as approximately 27.6 and 55.2 MPa.
Solve force equilibrium using εcu = 0.003, a = β₁c and elastic-perfectly plastic steel. Deduct 0.85f′c from the stress of top steel inside the concrete block. Sum moments of the compression forces about the tension steel.
Use φ = 0.65 below εty and interpolate to 0.90 at εty + 0.003, with εty = fy/Es. Check tension control and As,min = max(3√f′c, 200)bw d / min(fy, 80 ksi).
Rectangular section · pure bending · Within screening limits
Inputs
Section width b
14 in
Overall depth h
30 in
Tension steel depth d
27 in
Tension steel As
4.8 in²
Top steel As′
0 in²
Concrete strength f′c
8,500 psi
Steel yield strength fy
60 ksi
Factored moment Mu
450 kip·ft
Calculated values
Design moment φMn
552.45 kip·ft
Stress block depth a
2.85 in
Neutral axis depth c
4.38 in
Net tensile strain εt
15,491 με
Strength factor φ
0.9
Whitney factor β₁
0.65
Tension-controlled limit
5,069 με
Nominal moment Mn
613.83 kip·ft
Minimum tension steel As,min
1.742 in²
Concrete compression Cc
288 kip
Top steel force Cs,net
0 kip
Tension steel force Ts
288 kip
Screening
Tension controlled · Moment utilization 81.5%
Bending strength · Within limit
Minimum tension steel · Within limit
Tension control · Within limit
Positive pure bending of a nonprestressed rectangular beam. The calculation excludes combined axial force, shear, anchorage and the minimum-steel exception in §9.6.1.3.