ACI 318-19 §7.3 / §7.6 / §24.4

One-Way Slab Flexure & Thickness Calculator

Check one-way slab span-to-depth, flexure, spacing and transverse shrinkage-temperature steel for a unit-width strip.

Edit inputs ↓

Inputs

Solid slab · unit-width strip

Slab & demand
Bar layout
φMn / strip 11.16kip·ft/ft
Thickness min 7.2in
Steel min 0.173in²/ft
Flex spacing 18in
AnatomyDiagrammatic scale
Parameter-linked slab drawing. Diagrammatic scale. SIMPLE SPANhℓ 12 ftd 6.94 ins 10 in

Screening

Within screening limits
Strip moment utilization62.7%
Tension controlled37.3% below the threshold
  • Flexural strengthMu ≤ φMn for the design strip
    Within limit
  • Tension controlεt ≥ εty + 0.003 per §7.3.3.1
    Within limit
  • Minimum strip reinforcementFlexural and transverse T&S steel each ≥ 0.0018Ag
    Within limit
  • Minimum clear bar spacingClear spacing ≥ max(1 in, db); check aggregate size separately
    Within limit
  • Maximum bar spacingFlexural and T&S bar spacing within upper limits
    Within limit
  • Minimum thicknessh meets the span-to-depth shortcut
    Within limit

Normalweight, solid nonprestressed slabs. The thickness shortcut assumes no damage-sensitive attachments. Check load combinations, one-way shear, anchorage and the crack-control spacing of §24.3 separately.

Calculation readout
QuantityValue
Strip design moment φMn11.16 kip·ft/ft
Minimum slab thickness7.2 in
ACI minimum strip steel0.173 in²/ft
Maximum flexural spacing18 in
Effective depth d6.938 in
Provided flexural steel0.372 in²/ft
Provided transverse T&S steel0.2 in²/ft
Maximum T&S spacing18 in
Grade-scaled reference (legacy)0.173 in²/ft
Net tensile strain εt29,338 με
Strength factor φ0.9

How the check works

Code basis ↗
  1. Apply ℓ/20, ℓ/24, ℓ/28 or ℓ/10 and the factor (0.4 + fy/100,000). A thinner slab requires a calculated deflection check.
  2. Find d from h, clear cover and half of the bar diameter. Calculate Aₛ per unit width and the tension-controlled φMn using the same strain-compatible rectangular block as the beam tool.
  3. ACI 318-19 §§7.6.1.1 and 24.4.3.2 use 0.0018Ag for flexure and deformed T&S steel. Use the ACI 318-19 minimum for screening. Check upper spacing of min(3h, 18 in) for flexure and min(5h, 18 in) for T&S. Clear spacing must also reach max(1 in, db); verify the aggregate-size term separately.