1 Vpp Sine Wave to dBm into 75 Ω
Convert 1 Vpp measured across 75 Ω into RMS voltage, about 1.67 mW and 2.22 dBm.
Results
Preset estimate- Conducted power
- 0.001667 W
- Load voltage
- 0.353553 Vrms
- Load voltage
- 1 Vpp
Transmitter output
- Milliwatts
- 1.666667 mW
- Microwatts
- 1,666.666667 µW
- Load resistance
- 75 Ω
Radiated power & antenna reference
- EIRP
- 2.218 dBm
- Equivalent isotropic watts
- 0.001667 W
- ERP
- 0.068 dBm
- Equivalent dipole watts
- 0.001016 W
- Gain relative to isotropic
- 0 dBi
- Gain relative to dipole
- -2.15 dBd
| dBm | Watts | Vrms · 50 Ω | Vpp · 50 Ω | Vrms · 75 Ω | Vpp · 75 Ω |
|---|---|---|---|---|---|
| -30 | 0.000001 | 0.007071 | 0.02 | 0.00866 | 0.024495 |
| 0 | 0.001 | 0.223607 | 0.632456 | 0.273861 | 0.774597 |
| 10 | 0.01 | 0.707107 | 2 | 0.866025 | 2.44949 |
| 20 | 0.1 | 2.236068 | 6.324555 | 2.738613 | 7.745967 |
| 30 | 1 | 7.071068 | 20 | 8.660254 | 24.494897 |
| 40 | 10 | 22.36068 | 63.245553 | 27.386128 | 77.459667 |
Worked example
One volt peak to peak is 0.5 V peak and about 0.3536 Vrms for a sine wave. Squaring RMS voltage and dividing by 75 Ω gives about 1.667 mW or 2.22 dBm.
An RF generator can specify its level into 75 Ω. Confirm that the scope sees that termination, especially when adapting between BNC systems. The calculation uses voltage measured across the terminating load.
- Conducted power
- 2.218 dBm
- Conducted power
- 0.001667 W
- Load voltage
- 0.353553 Vrms
- Load voltage
- 1 Vpp
Formulas & assumptions
- P(W) = 10^((dBm − 30) / 10). dBm = 10 log₁₀(P(W)) + 30.
- Vrms = √(P × R) across a matched resistive load. Vpp = 2√2 × Vrms for a sine wave.
- Gain (dBi) = gain (dBd) + 2.15. EIRP = conducted dBm − feed loss + gain in dBi. ERP = EIRP − 2.15 dB.
Voltage conversions are for a sine wave across the stated matched load. A scope in high-impedance mode can show a different source voltage. Modulated RF often needs separate peak and average measurements.
When the input is ERP or EIRP, the tool works back to conducted power before converting to port voltage.
Questions & answers
Does 1 Vpp in a 75 Ω system always mean 2.22 dBm?
That conversion applies to a sine wave across the 75 Ω load. Other waveforms can have different RMS voltage at the same peak-to-peak reading.
What happens to 1 Vpp power if the matched load is 50 Ω?
At 1 Vpp a matched 50 Ω sine-wave load receives 2.5 mW. It draws more power at the same voltage than 75 Ω.