10 W ERP to EIRP and Conducted RF Power
Convert 10 W ERP to EIRP, then back-calculate conducted power for a 6 dBi antenna with 1 dB feed loss.
Results
Preset estimate- Conducted power
- 5.188 W
- Load voltage
- 16.1059 Vrms
- Load voltage
- 45.554365 Vpp
Transmitter output
- Milliwatts
- 5,188.000389 mW
- Microwatts
- 5,188,000.38929 µW
- Load resistance
- 50 Ω
Radiated power & antenna reference
- EIRP
- 42.15 dBm
- Equivalent isotropic watts
- 16.405898 W
- ERP
- 40 dBm
- Equivalent dipole watts
- 10 W
- Gain relative to isotropic
- 6 dBi
- Gain relative to dipole
- 3.85 dBd
| dBm | Watts | Vrms · 50 Ω | Vpp · 50 Ω | Vrms · 75 Ω | Vpp · 75 Ω |
|---|---|---|---|---|---|
| -30 | 0.000001 | 0.007071 | 0.02 | 0.00866 | 0.024495 |
| 0 | 0.001 | 0.223607 | 0.632456 | 0.273861 | 0.774597 |
| 10 | 0.01 | 0.707107 | 2 | 0.866025 | 2.44949 |
| 20 | 0.1 | 2.236068 | 6.324555 | 2.738613 | 7.745967 |
| 30 | 1 | 7.071068 | 20 | 8.660254 | 24.494897 |
| 40 | 10 | 22.36068 | 63.245553 | 27.386128 | 77.459667 |
Worked example
Ten watts ERP is 40 dBm referenced to a half-wave dipole. EIRP is 42.15 dBm, about 16.4 W. With 6 dBi gain and 1 dB loss, subtract the net 5 dB gain from EIRP to get conducted power.
Use this direction when you know the radiated reference and want to size a port setting. Output voltage refers to the resulting conducted power into your chosen load.
- Conducted power
- 37.15 dBm
- Conducted power
- 5.188 W
- Load voltage
- 16.1059 Vrms
- Load voltage
- 45.554365 Vpp
Formulas & assumptions
- P(W) = 10^((dBm − 30) / 10). dBm = 10 log₁₀(P(W)) + 30.
- Vrms = √(P × R) across a matched resistive load. Vpp = 2√2 × Vrms for a sine wave.
- Gain (dBi) = gain (dBd) + 2.15. EIRP = conducted dBm − feed loss + gain in dBi. ERP = EIRP − 2.15 dB.
Voltage conversions are for a sine wave across the stated matched load. A scope in high-impedance mode can show a different source voltage. Modulated RF often needs separate peak and average measurements.
When the input is ERP or EIRP, the tool works back to conducted power before converting to port voltage.
Questions & answers
What EIRP watt multiplier applies to an ERP watt value?
Multiply ERP watts by 10^(2.15/10), approximately 1.64.
Which gain should I subtract to recover conducted power from EIRP?
Subtract antenna gain in dBi and add back feed-line loss. A second conversion is needed if the starting power was ERP.