Rectangular waveguide TE₁₀ calculator

Find cutoff, single-mode span, guided wavelength, TE impedance and smooth-copper attenuation from EIA dimensions.

Readout

Rectangular waveguide modes
TE₁₀ CUTOFF
6.5571GHz
NEXT CUTOFF
13.114GHz
GUIDE λ
39.707mm
TE IMPEDANCE
498.97Ω
Single-mode safeBetween ideal TE₁₀ and next-mode cutoffs.
Waveguide TE₁₀ live schematicTE₁₀ transverse E-fieldEIA APERTUREa 22.86 mmbb 10.16 mmMode frequency windowGHzOperating 10 GHzCutoffSingle modeMultimodeTE₁₀ 6.557 GHzNext 13.11 GHzEVANESCENTTE₁₀ WINDOWHIGHER MODES

Mode thresholds & propagation

QuantityValue
TE₂₀ cutoff13.114 GHz
TE₀₁ cutoff14.754 GHz
Phase velocity397.07 Mm/s
Group velocity226.35 Mm/s
Wall attenuation0.10839 dB/m / 0.033036 dB/ft
Ideal air breakdown ceiling1047.3 kW peak

How to read this result

At and below TE₁₀ cutoff, propagating wavelength, velocity, impedance and attenuation are withheld. Above the next cutoff, TE₁₀ values are still reported, with a warning that other modes can propagate.

Cutoffs are ideal uniform-guide values. The single-mode band is the interval between TE₁₀ and the next cutoff, so manufacturer recommended bands are narrower. The dry-air breakdown estimate is a peak-field ceiling, with no operating power rating implied.