WR-28 Ka-band sensor interface

A Ka-band calibration segment is evaluated at 33 GHz before connecting a high-frequency sensor.

Readout

Rectangular waveguide modes
TE₁₀ CUTOFF
21.077GHz
NEXT CUTOFF
42.153GHz
GUIDE λ
11.806mm
TE IMPEDANCE
489.6Ω
Single-mode safeBetween ideal TE₁₀ and next-mode cutoffs.
Waveguide TE₁₀ live schematicTE₁₀ transverse E-fieldEIA APERTUREa 7.112 mmbb 3.556 mmMode frequency windowGHzOperating 33 GHzCutoffSingle modeMultimodeTE₁₀ 21.08 GHzNext 42.15 GHzEVANESCENTTE₁₀ WINDOWHIGHER MODES

Mode thresholds & propagation

QuantityValue
TE₂₀ cutoff42.153 GHz
TE₀₁ cutoff42.153 GHz
Phase velocity389.61 Mm/s
Group velocity230.68 Mm/s
Wall attenuation0.56225 dB/m / 0.17137 dB/ft
Ideal air breakdown ceiling116.22 kW peak

How to read this result

At and below TE₁₀ cutoff, propagating wavelength, velocity, impedance and attenuation are withheld. Above the next cutoff, TE₁₀ values are still reported, with a warning that other modes can propagate.

Cutoffs are ideal uniform-guide values. The single-mode band is the interval between TE₁₀ and the next cutoff, so manufacturer recommended bands are narrower. The dry-air breakdown estimate is a peak-field ceiling, with no operating power rating implied.

Methods & references

Waveguide TE₁₀ examples

All 50 examples