WR-42 K-band test port

A 23.5 GHz guide models a smooth-copper interconnect in a test fixture.

Readout

Rectangular waveguide modes
TE₁₀ CUTOFF
14.051GHz
NEXT CUTOFF
28.102GHz
GUIDE λ
15.915mm
TE IMPEDANCE
470Ω
Single-mode safeBetween ideal TE₁₀ and next-mode cutoffs.
Waveguide TE₁₀ live schematicTE₁₀ transverse E-fieldEIA APERTUREa 10.668 mmbb 4.318 mmMode frequency windowGHzOperating 23.5 GHzCutoffSingle modeMultimodeTE₁₀ 14.05 GHzNext 28.1 GHzEVANESCENTTE₁₀ WINDOWHIGHER MODES

Mode thresholds & propagation

QuantityValue
TE₂₀ cutoff28.102 GHz
TE₀₁ cutoff34.714 GHz
Phase velocity374.01 Mm/s
Group velocity240.3 Mm/s
Wall attenuation0.34352 dB/m / 0.10471 dB/ft
Ideal air breakdown ceiling220.52 kW peak

How to read this result

At and below TE₁₀ cutoff, propagating wavelength, velocity, impedance and attenuation are withheld. Above the next cutoff, TE₁₀ values are still reported, with a warning that other modes can propagate.

Cutoffs are ideal uniform-guide values. The single-mode band is the interval between TE₁₀ and the next cutoff, so manufacturer recommended bands are narrower. The dry-air breakdown estimate is a peak-field ceiling, with no operating power rating implied.

Methods & references

Waveguide TE₁₀ examples

All 50 examples