Dielectric-loaded custom waveguide

A homogeneous dielectric insert lowers the cutoff of a custom 31 × 13 mm aperture.

Readout

Rectangular waveguide modes
TE₁₀ CUTOFF
3.2453GHz
NEXT CUTOFF
6.4906GHz
GUIDE λ
77.788mm
TE IMPEDANCE
405.67Ω
Single-mode safeBetween ideal TE₁₀ and next-mode cutoffs.
Waveguide TE₁₀ live schematicTE₁₀ transverse E-fieldEIA APERTUREa 31 mmbb 13 mmMode frequency windowGHzOperating 4.15 GHzCutoffSingle modeMultimodeTE₁₀ 3.245 GHzNext 6.491 GHzEVANESCENTTE₁₀ WINDOWHIGHER MODES

Mode thresholds & propagation

QuantityValue
TE₂₀ cutoff6.4906 GHz
TE₀₁ cutoff7.7388 GHz
Phase velocity322.82 Mm/s
Group velocity125.41 Mm/s
Wall attenuation0.13497 dB/m / 0.041139 dB/ft
Ideal air breakdown ceiling—

How to read this result

At and below TE₁₀ cutoff, propagating wavelength, velocity, impedance and attenuation are withheld. Above the next cutoff, TE₁₀ values are still reported, with a warning that other modes can propagate.

Cutoffs are ideal uniform-guide values. The single-mode band is the interval between TE₁₀ and the next cutoff, so manufacturer recommended bands are narrower. The dry-air breakdown estimate is a peak-field ceiling, with no operating power rating implied.

Methods & references

Waveguide TE₁₀ examples