WR-137 upper C-band bench

A 7.2 GHz waveguide section is used in a bench feed with low-loss walls.

Readout

Rectangular waveguide modes
TE₁₀ CUTOFF
4.3013GHz
NEXT CUTOFF
8.6027GHz
GUIDE λ
51.922mm
TE IMPEDANCE
469.77Ω
Single-mode safeBetween ideal TE₁₀ and next-mode cutoffs.
Waveguide TE₁₀ live schematicTE₁₀ transverse E-fieldEIA APERTUREa 34.849 mmbb 15.799 mmMode frequency windowGHzOperating 7.2 GHzCutoffSingle modeMultimodeTE₁₀ 4.301 GHzNext 8.603 GHzEVANESCENTTE₁₀ WINDOWHIGHER MODES

Mode thresholds & propagation

QuantityValue
TE₂₀ cutoff8.6027 GHz
TE₀₁ cutoff9.4878 GHz
Phase velocity373.83 Mm/s
Group velocity240.42 Mm/s
Wall attenuation0.053322 dB/m / 0.016253 dB/ft
Ideal air breakdown ceiling2637 kW peak

How to read this result

At and below TE₁₀ cutoff, propagating wavelength, velocity, impedance and attenuation are withheld. Above the next cutoff, TE₁₀ values are still reported, with a warning that other modes can propagate.

Cutoffs are ideal uniform-guide values. The single-mode band is the interval between TE₁₀ and the next cutoff, so manufacturer recommended bands are narrower. The dry-air breakdown estimate is a peak-field ceiling, with no operating power rating implied.

Methods & references

Waveguide TE₁₀ examples

All 50 examples